Installation

8XP Zone Expander

The Premier 8XP Zone Expander has:
8 fully programmable zones
8 fully programmable –ve applied outputs
1 programmable auxiliary input
A fully adjustable speaker output
Expander Layout
Engineers
Keypad
Tamper
Switch
Interface
NETWORK IN
+ -
Remote
D
S
Zones
1 & 2
ON
1
Aux
12V
Zones
3 & 4
-
+
Aux
Input
YPE0123456
Com Port
Aux
Speaker
Input
Output
Connecting Expanders
Expanders are connected to the network terminals located
at the bottom left hand corner of the control panel (see
pages 13 & 14 for connection details).
Expander Addressing
Each Expander must be assigned a different address using
the DIL switches located in the centre of the PCB. The table
below shows the expander addressing:
Address
DIL 1
DIL 2
1
On or off
2
Off
!
Never set two expanders on the same network to the
same address.
18
Network
Terminals
Power LED
NETWORK OUT
+ -
Tamper
T
R
T
R
Disable
Power
2 3 4
-
1
2
3
4
5
6
7
8
Spk
OUTPUTS
Address
Outputs
Switch
1 to 8
DIL 3
DIL 4
Off
Off
Off
On
Off
Off
Zone Numbering
The table below shows the zone allocation when the
expanders are installed:
Address
1
2
Expander Zones
The expander has eight programmable zones (see page 21
for wiring details). Each zone is also fully programmable
(see page 34 for programming details).
!
When using an 8XP Zone Expander, the wiring
configuration must always be selected as 'Double
EOL' even if wired as Double Pole.
Expander Auxiliary Input
The expander has one programmable input. This auxiliary
input can be used to monitor auxiliary devices such as
Zones
tamper loops etc. Wire as per Aux Tamper shown on page 22
5 & 6
(see page 53 for programming details). The system will
respond as follows:
Aux
12V
Input Status
0V Applied
Zones
7 & 8
0V Removed
!
For further details on how the input status affects the
system please refer to page 53.
Expander Outputs
The zone expander has eight programmable outputs, which
can be used to drive auxiliary devices such as LED's,
sounders or relays etc. Wire as per Panel Outputs shown on
page 24 (see page 53 for programming details). The
electrical characteristics for the outputs are shown below:
Outputs
1 to 8
Expander Speaker Output
The expander has an output that can be used for driving up
to one 16Ω or two 8Ω loudspeakers (see page 22 for wiring
details).
Expander Com Port
The Com Port can be used to connect a PSU200 montored
1
2
3
4
power supply or a RadioPlus Inteligent Receiver.
1
2
3
4
Expander Lid Tamper
The lid tamper of each expander can be disabled if required
by fitting a jumper link across the centre and right hand pins
of the 'Enable Tamper' pins (JP2) leaving the left hand pin
free. These pins are located to the left of the address DIL
switch just beneath the fuse.
Premier 24 Installation Manual
Zones
9 - 16
17 - 24
System Response
Input Secure
Input Active
Max Current
100mA
Switched -ve
Type