RESERVOIR TO PLASTIC UNION
1 . D i sco n n e ct t h e un i t fro m p o we r
s o ur ce .
2. Remove those parts necessary to
expose the reservoir (shelves).
3 . D i s c o n n e ct t h e un i o n co n ne cti on a t th e
b o t t o m o f t h e ca bi n e t b e h in d th e gr ille .
Drain the water into a container.
Union Connection
D i s co n n e c t th e co mp re ssio n n u t fr om
t h e re s e rv o i r co n ne cti on .
P u l l t h e co m p re ssi o n n ut o ff th e tu b in g
a n d p ul l t h e t u bi n g fro m th e b a ck o f th e
u n i t t hr o u g h t h e b o tto m.
Th e re p la ce m en t tu bi n g is in sta lled by
p u s h i n g i t t h r o u g h t h e g r o m m e t i n s i d e
t he f r es h f o o d comp a rtme n t a nd
p ul l i ng t h e t u b in g fro m th e ba ck o f th e
u ni t t hr o u g h th e g ro mmet. L e a ve
e n o u g h sl a ck to ma ke n e ce ssar y
co n n ec t i o n s. In stal l a ti o n may b e
fa c i l i t a te d b y co ati n g th e tu b ing with
s i l i c o n e g re a se to h e l p e ase the tub in g
th ro u g h th e g ro mme t.
7. Inst all the part s in the r evers e or der
of rem oval and avoid any cr imps,
bends or kinks that might caus e a
rest rict ion in the tubing.
L
Tur n on t he elect rical supply and
act ivat e t he chilled wat er dis pens er .
Draw six or seven glasses of water to
r emove any tr apped air and check all
connections f or leaks.
PLASTIC UNION TO FOUNTAIN
Disconnect t he unit f rom pow er
source.
Disconnect the com pression nut from
t he union at the bot tom of t he c abi net
behind t he grille. Dr ain the w ater into
a container .
D isconnect t he compr ession nut from
the tube connect or on t op of the
f o u n t a i n h o u s i n g .
Pull the compr ession nut f rom the
supply tubing fountain connec tor end.
P u l l t h e s u p p l y t u b i n g d o w n t h r o u g h
t h e d o o r b u s h i n g a n d h o l l o w h i n g e p i n .
I nstall t he r eplacement supply tubing
by pushing it up t hrough t he bottom
d o o r b u s h i n g a n d h o l l o w h i n g e p i n .
Pull enough thr ough to mak e the
connect ions.
Aft er all connections have been made,
reconnect the unit to the power s upply
and
activat e the
chilled w ater
dispenser . D raw six or seven gl ass es
of water to remove any trapped air and
check all connect ions for leaks.
lnst all any rem aining part s prev iously
rem oved.