Maytag 56326 Service Manual page 149

Maytag 56326 side-by-side and top mount refrigerator
Table of Contents

Advertisement

RTC19A
POWER REOUIREMENT
1 IqVAC
60 Hz
oPERATTNG
AMPS. (MAX)
6 . 6
REFRTGERANT
GHARGE R-1 2(02)
c . u
coMPBES$oR
0rL CHAnGE (02)
8 . 5
COMPRESSOR
775 BrU
CABINET LINER
H I G H I M P A C T
L A M I N A T E D
P O L Y S T Y R E N E
DOOR LINERS
H I G H I M P A C T
L A M I N A T E D
P O L Y S T Y R E N E
FOUNTAIN HEATER
O h m s
Watts
N O N E
CABINET INSULATION
F O A M
TEMPERATURE
CONTROL
(At Normal)
C u t Q u t ( P l u s o r M i n u s 1 . 5 ' F )
C u t - l n ( P l u s o r M i n u s 1 . S o F )
+ 23"F
+ 33oF
CONDENSER
F A N
C O O L E D
CAPILLARY TUBE
L e n g t h
D i a m e t e r
8 f t .
.036" r.D.
DEFROST
THERMOSTAT
Cut-Out (Plus or minus 6"F)
C u t - l n ( P l u s o r m i n u s 6 o F )
+ 47"F
+ 1 5 0 F
DEFROST
TIMER
Defrost Cycle
Defrost Time
A F T E R
C O M P R E S S O R
R U N S 8 H R S .
(rorAL)
8 H R S ,
DEFROST HEATER
O h m s
Watts
28
450
DEFR0ST AMPS. (MAX.)
DIVIDER CHANNEL HEATER
O h m s
Watts
1 323
1 0
PERFORMANCE TEST DATA
The laboratory test data in this chart was obtained under the following conditions: (1) power
source of 1 15V AC, 60 Hz, (21 no door openings, (3) no load, (4) customer control(s) set at
mid-point. The pressures and wattages shown were taken: (a) during a normal running cycle,
(b) with lreezer temperature near 00F (refrigerator temperature, if applicable, near +380F), {c)
no sooner than 5 minutes after compressor start-up. In the home, measurements will vary
depending upon environmental and usage conditions.
70"F
(Ambient)
900F
(Ambient)
1 1 0 " F
(Ambient)
ok Operating Time
KW H | 2 4 H o u rs
S u c t i o n P r e s s u r e ( p s i g )
H i g h S i d e P r e s s u r e ( p s i g )
R u n n i n g W a t t s
30-40
1 . 6 - 2 . 0
0-3
1 00-1 20
1 65-200
55-70
2.5-3.3
0-3
1 30-1 50
1 6 5 - 2 1 0
1 0 0
3. 8- 4.9
o-4
140-174
1 55-200
9-7

Advertisement

Table of Contents
loading

Table of Contents