3 . U n so l de r t h e yo de r lo o p tu b in g a t
p o i n t s " A " a n d " 8 " .
Top
Mount
C r i m p a n d so ld e r th e yo d er tu b in g a t
p o i n t " A " .
S ol d er t h e spe ci a l a ccess fi tting to
t u b e r e m o v e d a t p o i n t " 8 " .
P re s s u ri ze th e syste m to 2 5 0 l b s. with
t h e d ry n i t ro ge n . L ea k te st the jo in t,
u s i n g a s o a p s o l u t i o n .
C h ec k t h e p re ssu re g a u ge . l f th e p r es-
su re de c re a se s, a le a k exi sts. lt m a y
b e n e ce s sa ry t o al l o w u p to 2 4 h o ur s
to p a s s i n o rd e r to de te rmi ne th is. lf a
l e a k do e s n o t exi st, r eco n n ect th e tu b -
i n g , ev a c u a t e a nd r ech a rg e the sys-
t e m .
l f t h e y o d e r l o op is le a kin g , a sp e cial
k i t ca n b e o rd e red for i nsta l li ng a r e -
si s ta n c e h e a te r wi re . Co mp le te in -
st ru c t i o n s a re i n clu d e d w ith the kit. lt
is not necessary to leave the refriger-
at o r i n o p e ra tive wh i le yo u o rde r th e
k i t . Y o u sh o u ld re con n e ct th e syste m
ex c l u d i n g t h e yo d er lo o p a s fol lo ws:
I n st a l l a n e w d ri e r. l n ste ad o f co n n e ct-
i n g i t t o p o i n t " A " , c o n n e c t i t t o p o i n t
" B " . T h i s w i l l e x c l u d e t h e y o d e r l o o p
f r om t h e re f r i ge ra n t syste m.
9. E vacuat e and r echar ge the sy s tem .
10. Leak t est all tubing joint s and tes t r un
the r ef rigerator .
1 1 . P i n c h t h e p r o c e s s t u b e a n d c u t t h e
service valve off t he t ubing. Solder the
joint and check f or leaks.
TESTING YODER LOOP
Side-By-Side Models
1. D isconnect unit f rom pow er sour ce.
2 . I nstall a ser vice valve on the proc es s
t ube and vent the r efrigerant outsi de.
3 . U nsolder t he yoder loop t ubing at
p o i n t s " A " a n d " 8 " . ( s e e d r a w i n g ) .
4 . C r i m p a n d s o l d e r t h e y o d e r t u b i n g a t
p o i n t " A " .
5 . Solder t he special access fi tting to
t u b e r e m o v e d a t p o i n t " 8 " .
6. Pr essur ize the system to 250 lbs . w ith
the dry nitr ogen. Leak t est the j oint
u s i n g a s o a p s o l u t i o n .
7. Check the pressure gauge. l f the
pressure decreases, a leak ex is ts . l t
may be necessar y to allow up to 24
hour s to pass in or der to deter mine
this. lf a leak does not exist , r econnec t
the tubing, evacuate and rechar ge the
system.
lf t he yoder loop is leaking, a spec ial ki t
c an be or dered for installing a r es is tanc e
h eat er wire. Com plete instr uctions are
included wit h the kit. lt is not nec ess ar y
to leave the r efrigerant inoper ativ e w hil e
you order t he kit. Y ou should rec onnect
the syst em excluding t he yoder loop.
To exclude t he yoder loop, connec t c om-
p ressor discharge line dir ect ly t o c onden-
s e r b y c o n n e c t i n g t h e t u b i n g a t p o i n t " A "
t o p o i n t " 8 " ,
Suction
Tube
4 .
5 .
6 .
7 .
3-9