T R OU B L E
P OSSIBL E CAUS E
R E M E D Y
E . U n i t r u n s c o n t i n u o u s l y
but there is no cooling
in
refrigerator and
freezer
compad-
ments.
1.
Substantial loss of sealed sys-
tem charge (low wattage read-
i n g s ) .
2.
Restricted capillary or drier on
high side (low wattage readings
w h i l e r u n n i n g ) . W i l l c y c l e o n
overload when unit tries to start
after defrost cycle, or after hav-
ing been shut off and restriction
is still present.
3.
Defective compressor.
1.
Locate and repair leak before
recharg i ng.
2.
Replace defective pad or parts.
3 .
R e p a i r o r r e p l a c e .
F . U n i t
r u n s
c o n t i n -
uously. The refrigera-
tor
and
freezer
compartment are both
too cold (normal wat-
t a g e r e a d i n g ) .
1 . Temperature control is defec-
tive (shorted contacts or not
adjusted.
Freezer control not adjusted
properly.
2 .
1 .
R e p l a c e o r a d j u s t a s r e q u i r e d .
2.
See "Freezer Cold Control" for
proper adjustment.
G . U n i t
r u n s
c o n t i n -
uously. Refrigerator
compaftment not cold
enough but freezer
compartment
is
c o l d e r t h a n n o r m a l .
1.
Air duct from freezer to refri-
gerator is blocked (normal wat-
t a g e r e a d i n g s ) .
1 .
R e m o v e w h a t i s b l o c k i n g t h e a i r
d u c t . S e e
" A i r F l o w D i a g r a m " .
7-3