TR O U B L E
POSSIBL E CAUSE
R EMED Y
R . Excessively noisy but
works normally other-
wise.
1 . Refrigerator not level or firmly
setting on all four corners.
Structural weakness in floor.
Compressor mounling defec-
tive.
Poor tubing dress.
Compressor operation is noisy
due to inherent conditions.
Unit base mounting loose.
Defrost water pan raltles.
Freezer or condenser fan is
noisy. May have defective mo-
tor.
Containers inside refrigerator
rattle.
2 .
3 .
4 .
5 .
6
7
8 .
9 .
1.
Level the unit, lower the level-
ing legs if necessary to make
sure thal unit is firmly on the
floor.
2.
Advise customer.
3.
Check and replace if necessary.
4.
Adjust tubes so they do not
touch.
5.
Advise customel.
6.
Tighten loose part or parts.
7.
Adjust pan or install foam pad
if necessary.
8 .
R e p l a c e .
Advise customer
S. Defrost water
dis-
p o s a l p r o b l e m .
1. Water frozen in drain trough
(defective defrost timer, radiant
heater or defrost thermostat),
2.
Restriction in drain system.
3 .
M a y n e e d h e a t e r k i t i n s t a l l e d i n
evaporator pan.
4.
Separation of heat exchanger.
1.
Replace defective part or parts.
2 .
C l e a n d r a i n s y s t e m .
3 .
C h e c k a n d i n s t a l l p a d i f n e e d e d .
4.
Install Heat Exchanger Sepa-
ration Kit, RA43302.
7-7