SPECIFICATIONS & CLEARANCES FOR REAR VENT SYSTEM
USE ONLY DURAVENT 5"X8" COAXIAL PIPES AND VENTING COMPONENTS.
31 15/32
35 31/32
USE A MINIMUM OF A 6" DURAVENT PIPE SECTION
45°
TO CONNECT THE REAR VENT STATER COLLAR TO
10"
THE HORIZONTAL CAP. SLIDE HORIZONTAL CAP
OVER THE 6" PIPE AS FAR AS NEEDED.
Adjacent Walls:
A wall, perpendicular to and in front of the appliance front
facing must be at least 10" from the firebox opening. A
wall at 45° to the front and starting at the appliance's
outer edge is permitted. Projections behind this wall (shaded
area) are permitted.
COMBUSTIBLE MANTEL
TRIANGULAR AREA. FOR
MANTEL DEPTH, INCREASE
1
BY 2". MANTEL MAY BE LOWERED
DECREASED IN THE SAME MANNER
2
8" MANTEL
DEPTH (WIDTH)
14" DISTANCE
MINIMUM TO
8" MANTEL
49 1/2" MIN.
CLEARANCE TO
COMBUSTIBLE
ABOVE UNIT
& MINIMUM
CEILING HEIGHT
4 21/32"
GAS INLET
NON-COMBUSTIBLE
HEARTH PROTECTOR
REQUIRED
12"
DEPTH
NOTE:
FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR,
HEARTH PROTECTOR MAY BE REDUCED BY 2".
IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
WARNING: Do not cover the 2" faceplate border of the unit with combustible materials.
Figure 7: SPECIFICATIONS AND CLEARANCES FOR DXV35 REAR VENTED SYSTEM ONLY!!
NOTE
:
MAXIMUM HORIZONTAL RUN ALLOWED IS 9" FOR STRAIGHT-OUT-THE-BACK AND
CORNER INSTALLATIONS. ONLY THE VENT CONFIGURATIONS SHOW ABOVE ARE ALLOWED!!
NOTE: WHEN INSTALLING THE DXV35 USING THE REAR VENT OPTION AT ALTITUDES ABOVE 4000
GAS INPUT RATE MUST BE REDUCED (DERATED) BY 4% FOR EVERY 1000 FEET
FEET, THE
ABOVE SEA LEVEL.
INSTRUCTIONS.
MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
11 1/16
22 9/32
16 3/32
15 13/32
1/2 to
2 1/2
MUST REMAIN IN THIS
EVERY 1" INCREASE IN
HEIGHT ABOVE GRILL
IF DEPTH IS
8" THIMBLE
& 5"X8"
HORIZONTAL
TERMINATION
1 5/32
CAP
31-1/2
22-5/8
2 7/16"
16 3/32
CONTACT YOUR GAS SUPPLIER FOR PROPER DERATING
2X4 WALL
19 19/32
6" LENGTH MINIMUM
9" LENGTH MAXIMUM
MINIMUM FRAMING DIMENSIONS
FOR THE DIRECT VENT
31-1/2
HEIGHT
(800 mm)
37 1/8
WIDTH
(943 mm)
16-1/8
DEPTH
(410 mm)
14 MIN.
FROM TOP
OF GRILL
TO 8" MANTEL
43 3/16
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL
(BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE
ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
22
44 29/32
4 3/32 FOR 2X4 WALLS
2 19/32 FOR 2X6 WALLS
45 Deg L
64 5/32
4 3/32 FOR 2X4 WALLS
2 19/32 FOR 2X6 WALLS
CORNER INSTALLATION
FOR 2x4 WALLS, USE
THESE DIMENSIONS.
FOR 2X6 WALLS, MOVE
FIREPLACE CLOSER TO
WALLS IN EACH
DIRECTION 2".
USE A 9" PIPE SECTION
IF YOU DESIRE A WIDER
DIAGONAL
MEASUREMENT.
8" COMBUSTIBLE MANTEL
32
28 15/16
35 31/32
10 13/16
44 29/32
31 1/2
1 7/8