Mendota DXV-35 DEEP TIMBER II Installation & Operating Instructions Manual
Mendota DXV-35 DEEP TIMBER II Installation & Operating Instructions Manual

Mendota DXV-35 DEEP TIMBER II Installation & Operating Instructions Manual

Gas direct vent fireplace with hearthglo sealed combustion system
Table of Contents

Advertisement

GAS DIRECT VENT FIREPLACE
Model DXV-35 DEEP TIMBER II with Direct Rear Vent Option
FLAT FRONT
INSTALLATION & OPERATING INSTRUCTIONS
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance
or additional information consult a qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY:
IF YOU SMELL GAS:
1.
OPEN WINDOWS.
2.
DO NOT TOUCH ELECTRICAL SWITCHES.
3.
DO NOT TRY TO LIGHT ANY APPLIANCE.
4.
EXTINGUISH ANY OPEN FLAME
5.
DO NOT USE THE PHONE IN YOUR BUILDING.
6.
IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S
PHONE.
7.
FOLLOW THE GAS SUPPLIERS INSTRUCTIONS.
8.
IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE
DEPARTMENT.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
WITH HEARTHGLO SEALED COMBUSTION SYSTEM
IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER!
MENDOTA
NO. DT2-0507
FOR YOUR SAFETY
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED
INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. DO NOT STORE
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE
WARNING:
DO NOT OPERATE THIS APPLIANCE WITH THE GLASS
REMOVED, CRACKED OF BROKEN. REPLACEMENT OF GLASS
SHOULD BE DONE BY A
WARNING:
MENDOTA GAS FIREPLACES ARE HEAT PRODUCING
APPLIANCES. DO NOT BURN WOOD, PAPER OR OTHER
MATERIALS IN THE FIREPLACE. THE FIREPLACE IS
DESIGNED AS A SUPPLEMENTAL HEAT SOURCE. IT IS
ADVISABLE TO HAVE AN ALTERNATE HEAT SUPPLY.
BAY FRONT
LICENSED OR QUALIFIED PERSON.

Advertisement

Table of Contents
loading

Summary of Contents for Mendota DXV-35 DEEP TIMBER II

  • Page 1 MENDOTA GAS DIRECT VENT FIREPLACE WITH HEARTHGLO SEALED COMBUSTION SYSTEM Model DXV-35 DEEP TIMBER II with Direct Rear Vent Option FLAT FRONT BAY FRONT INSTALLATION & OPERATING INSTRUCTIONS NO. DT2-0507 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
  • Page 2: Table Of Contents

    NATURAL TO LP GAS CONVERSION _______________________________________________________________________ 51 REPLACEMENT PARTS ___________________________________________________________________________________ 53 MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION ______________________________________________ 54 LABEL REPRESENTATION ________________________________________________________________________________ 56 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ______________________________________ 57 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY ___________________________________ 60...
  • Page 3: Building Permit And Installation Inspection Approval Requirements

    Institute - ANSI Gas Appliance Safety Standards The Mendota Gas DXV Fireplace has been tested and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI FIREPLACE INCLUDES A HEARTHGLO SEALED COMBUSTION SYSTEM, 6-PIECE CERAMIC FIBER LOG SET &...
  • Page 4: Congratulations

    Fireplace and replace any part of the control system and any gas control, which has been under water. DO NOT use this fireplace if the burner does not light immediately. Turn unit off and call Mendota approved service person if there is any delay in burner light-off.
  • Page 5: Locating The Fireplace And General Information

    The DXV Fireplace must be installed and serviced by a Mendota approved service person. Any adjustments to burner, pilot, logs or coal bed must be made by a Mendota approved service person. Pilot flame must be checked with voltmeter. Pilot flame must register ALWAYS a minimum of 325 on Millivolt meter.
  • Page 6: Top Vent And Rear Vent Options Discussion

    This Mendota Fireplace can be vented using AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY brands of coaxial pipe off the top or using 5”x8” coaxial pipe off the rear. Use only Mendota specified vents and vent caps when in- stalling your fireplace. Closely follow venting locations, directions and requirements provided in this Manual. Observe the restric- tions related to vent position on exterior of home (see PG.
  • Page 7: Gas Supply Requirements

    GAS SUPPLY LINE SIZING The Mendota Gas Fireplace comes equipped with a 3/8" N.P.T. (1.Ocm) inlet on the main gas valve. This may be removed if a ½" flexible connector is used. Gas supply piping can enter the Fireplace cabinet from either the left or right side.
  • Page 8: Gas Pressure Requirements

    GAS PRESSURE REQUIREMENTS A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS APPLIANCES CAN BE IMPROPER GAS PRESSURE! Such problems as changes in flame color or configuration, gas pilot or burner outages, intermittent operation, changes in heat output, excessive burner noise, etc. are nearly always the result of changes in gas pressure or improper gas pressure at the time of the installation.
  • Page 9: Exterior Vent Locations And Restrictions

    EXTERIOR VENT LOCATIONS AND RESTRICTIONS Figure 2: Exterior Vent Locations ALL MEASUREMENTS FROM CENTER LINE OF VENT CAP ∨ - ∧ - ≡ - Vent Terminal Air Supply Inlet Area where terminal is not permitted Clearance above grade, veranda, porch, deck, or balco- *Not to be installed above a meter/regulator assembly ny (*12 inches (30 cm) minimum).
  • Page 10: General Flue Venting Instructions

    Installation by unauthorized personnel; installation of any dam- aged component; unauthorized modification of vent system; installation of any components not approved by Mendota; failure to meet all clearance requirements; failure to properly twist-lock and positively seal all com- ponents. Consult local building codes before beginning the installation.
  • Page 11: General Installation Instructions

    CAUTION: Each installation must conform to all local, state and national codes. Refer to the national fuel gas code and local zoning and code authorities for details on installation requirements. The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code. In the ab- sence of local codes, the installation must conform to the most current edition of the National Fuel Gas Code ANSI Z223.1, also known as NFPA 54.
  • Page 12: Instructions For Venting Off The Top

    INSTRUCTIONS FOR VENTING OFF THE TOP This section covers all pertinent information regarding the installation of this DXV-35 Fireplace using the Top Vent option. Read this entire section thoroughly before at- tempting to install this DXV35 Fireplace. Failure to follow all directions and failure to observe all restrictions and clearances can result in property damage, bodily injury or can lead to death.
  • Page 13: Specifications & Clearances For Top Venting

    PG. 12 FOR INSTALLATION AT ALTITUDES ABOVE 7,500 FEET, FIRST CALL bows (see MENDOTA TECHNICAL HOTLINE FOR FURTHER INFORMATION ON THE STRICT REQUIREMENTS FOR INSTALLATIONS AT THESE ALTITUDES. Using 45 elbows requires 19" minimum opening to center (see PAGE 15). CAUTION: If 90ºelbows must be used...
  • Page 14: Top Flue Venting Components

    TOP FLUE VENTING COMPONENTS ITEM DESCRIPTION 12" VENT STACK 24" VENT STACK 36" VENT STACK 48" VENT STACK º GALVANIZED ELBOW º GALVANIZED ELBOW ADJUSTABLE WALL THIMBLE 6" or 7” PIPE (Duravent 6”/Amerivent 7”) ATTIC INSULATION SHIELD 12" ROOF FLASHING (0/12 TO 6/12) ROOF FLASHING (7/12 TO 12/12) STORM COLLAR VERTICAL VENT CAP...
  • Page 15: Flue Venting Requirements For Top Vent Systems

    FLUE VENTING REQUIREMENTS FOR TOP VENT SYSTEMS NOTE: FOR LP GAS & HIGH ALTITUDE, SEE PG. 15 Figure 6: DXV35 Vertical & Horizontal Vent Requirements NOTE : 9” MINIMUM VERTICAL PIPE CAN BE USED IF NO HORIZONTAL VENT SECTIONS GREATER THAN 6” (or 7”) ARE USED.
  • Page 16: L.p. Gas Minimum Height Horizontal Termination

    L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION L.P. G 4,000 . BUT BELOW 7500 FT.) AS OR LTITUDE ABOVE WALL THIMBLE REQUIRED TERMINATION CAP 6" COAX VENT (MIN.) 45° COAX VENT 45° COAX VENT 9" COAX VENT (MIN.) 19" (MIN.) 46 1/4" (MIN.) 85-03-00531 15 1/2"...
  • Page 17: Minium Rise Through The Wall Venting

    º used, a 3-foot vertical starter section must be used directly off the top of the fireplace. The DXV-35 Fireplace must be installed by a qualified Mendota approved serviceperson. IMPORTANT: REFER TO DRAWINGS ON PAGES 11-15 WHILE FOLLOWING THESE INSTRUCTIONS 1.
  • Page 18: Top Vent Components List

    TOP VENT COMPONENTS LIST MENDOTA # DESCRIPTION 45-01-00186 7" LENGTH 45-01-00187 12" LENGTH 45-01-00188 24" LENGTH 45-01-00189 36" LENGTH 45-01-00190 48" LENGTH 45-01-00191 ADJUSTABLE LENGTH 45-01-00192 45 DEG. ELBOW 45-01-00193 90 DEG. ELBOW 45-01-00194 WALL THIMBLE 45-01-00195 VERTICAL CAP 45-01-00196...
  • Page 19: Elevated Through The Wall Venting

    IMPORTANT: REFER TO DRAWINGS ON PAGES 11 -15 WHILE FOLLOWING THESE INSTRUCTIONS. The DXV-35 Fireplace must be installed by a qualified Mendota service person. 1. Position fireplace in desired location. See PG. 8 for guidelines on proper vent cap placement on exterior of home.
  • Page 20: Vertical Through The Roof Venting

    IMPORTANT: REFER TO DRAWINGS ON PAGES 1-15 WHILE FOLLOWING THESE INSTRUCTIONS The DXV-35 Fireplace must be installed by a qualified Mendota approved serviceperson. 1. Place the fireplace in its desired location. Drop a plum bob from the ceiling to the position of the fireplace flue exit.
  • Page 21 8. Height "*H" of top of vent cap can be determined as follows: "H" DIMENSION ROOF PITCH FEET METERS FLAT to 6/12 7/12 to 9/12 10/12 to 12/12 13/12 to 16/12 17/12 to 21/12 Complete installation with storm collar and vent cap.
  • Page 22: Instructions For Venting Off The Rear

    INSTRUCTIONS FOR VENTING OFF THE REAR ORIFICE SIZES REQUIREMENT: When the DXV35 employs the rear vent option, the rear burner orifice must be changed in the Natural Gas configuration to a #53 Spud Orifice (supplied with the Fireplace) and in an LPG configuration to a #61 Spud Orifice (supplied with the Fire- place).
  • Page 23: Specifications & Clearances For Rear Vent System

    MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE SPECIFICATIONS & CLEARANCES FOR REAR VENT SYSTEM USE ONLY DURAVENT 5"X8" COAXIAL PIPES AND VENTING COMPONENTS. 31 15/32 44 29/32 11 1/16 2X4 WALL 10 13/16 4 3/32 FOR 2X4 WALLS 2 19/32 FOR 2X6 WALLS...
  • Page 24: Rear Flue Venting Components

    (air intake) pipe joints. The Milpak silicate 1000 F sealant (#65- 06-00909) can be ordered through Mendota directly. NOTE: DO NOT SEPARATE TELESCOPING SECTIONS. THEY MUST BE USED AS COMPLETE ASSEMBLIES.
  • Page 25: Rear Flue Venting Requirements

    : A 9” MAXIMUM HORIZONTAL PIPE SECTION CAN BE USED WHEN VENTING THE DXV35 USING THE REAR VENT OPTION AGAINST A FLAT EXTERIOR WALL or IN AN EXTERIOR CORNER. WARNING MENDOTA RECOMMENDS THE USE OF DURAVENT 5”X8” COAXIAL PIPES AND FITTINGS. DURAVENT COMPONENTS PROVIDE THE MOST FLEXIBILITY SINCE DURAVENT HORIZONTAL TERMINATION CAPS SLIDE FULLY OVER THE 6”...
  • Page 26: Instructions For Horizontal Venting Against Exterior Wall

    INSTRUCTIONS FOR HORIZONTAL VENTING AGAINST EXTERIOR WALL Mendota recommends the use of Duravent 5”x8” coaxial pipes and fittings. Duravent components provide the most flexibility since Duravent horizontal termination caps slide fully over the 6” or 9” straight pipe section used. Using Amerivent pipes and components are limiting and will increase the minimum framing depth.
  • Page 27 WARNING: Only Horizontal Runs are allowed when using the Rear Vent Option. 1. Position fireplace in desired location against an exterior wall. See PG. 8 for guidelines on proper vent cap placement on the exterior of home. Check to determine if wall studs are in the way when venting system is attached.
  • Page 28: Corner Installation Using The Rear Vent Option

    Fireplace must be installed by a qualified service person. Mendota recommends the use of Duravent 5”X 8” coaxial pipes and fittings. Duravent components pro- vide the most flexibility since Duravent horizontal termination caps slide fully over the 6” or 9” straight pipe section used.
  • Page 29 WARNING: Only Horizontal Runs are allowed when using the Rear Vent Option. When planning to install the DXV35 Fireplace with the rear vent option in an outside corner, it is recommended that thorough calculations and measurements be made prior to any construction. The diagonal distance desired will de- termine the exact location on the wall where the Horizontal Termination Cap will be placed relative to the inside cor- ner.
  • Page 30: Dxv35 Rear Vent Conversion Instructions

    NOTE: You must order the Rear Vent Starter Collar Kit #AA-11-00645 from Mendota directly in order to perform this conversion. The DXV-35, as delivered, comes with the Top Exhaust and Air Intake Collars installed as shown below. The rear Exhaust and Air Intake ports are plugged.
  • Page 31 Step 1: Remove the Top Outer Jacket by first removing all the screws shown in the diagrams below. Careful- ly lift the rear end up and slide the Top Outer Jacket rearward. Set aside the Top Outer Jacket and screws for use in Step 3.
  • Page 32 STEP 2: Use an electric drill with a ¼” hex driver (with 6” extension) to remove the screws and parts from the top of the DXV-35 fireplace, as shown on left. IMPORTANT : Save Gaskets #65-02-00058 and 65-02- 00094 and screws # 50-01-00102 for use in STEP 2. STEP 3: Install all parts in sequence, as shown below.
  • Page 33 STEP 4: Remove the rear plug plates and gaskets as shown below. Save only Gasket #65-02-00095 and Screws #50-01-00102. Extra Screws are provided with this kit. STEP 5: Exhaust Collar #HA-30-00175 has a high temperature rated fiberglass gasket ma- terial installed on its flange face (see PAGE 29).
  • Page 34: Dxv Door Operation

    DXV DOOR OPERATION TO REMOVE DOOR (Flat shown) 1. Remove upper grill. 2. Open lower grill. 3. Place both thumbs on lower doorframe directly above Spring Loaded Door Holding Bar. 4. Reach fingers under Bar and pull Bar straight out from Fireplace front. 5.
  • Page 35: Deep-Timber Log Set Installation

    DXV-35XL DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS ORIFICE SIZES REQUIREMENT: When the DXV35 employs the rear vent option, the rear burner orifice must be changed in the Natural Gas configuration to a #53 Spud Orifice (supplied with the Fireplace). The front burner orifice remains unchanged at #42 for Natural Gas applications.
  • Page 36 2. Place Log “1” between Rear Brick Panel and rear-most burner tube – centered left to right in firebox and butted against rear brick. Leave a ¼” gap between front surface of log #1 and rear burner tube. 3. Place Log #2 between rear-most burner and middle burner tube as shown below. Place this log so that the pilot light notch and burner tube notches are positioned properly, as shown.
  • Page 37 4. Place Left Top Log #4 behind Log #2 and on top of Log #1 in the left rear corner area, as shown below. 5. Place right front log #6 behind front burner as shown. Slide this piece towards the right until it’s under structure touches the U-bend in the burner tube.
  • Page 38 6. Place left front log #5 behind front burner and to the left of Log #6, as shown. Slide to the right side and butt Log #5 against Log #6. 7. Slide Log #5 to the right side until it butts against the left edge of Log #6.
  • Page 39 8. Place log #3 as shown below – Align Pin in Log #2 with Hole in Log #3. Rotate Log #3 downward until Pin in Log #2 is inserted into hole in Log #3. 9. Log #3 rests on top of Log #2 and Log #6, as shown above. Rotate front end of Log 3 towards the right as far as its freedom allows.
  • Page 40 10. The completed log set shall look as depicted in the Figure below. 11. Add Large Chunk Coals, first, in the area shown in the diagram below.
  • Page 41 12. Space coals apart about ¼ inches side to side and bridge coals that span across the burner ports across the burner tube so that the coals do not plug any burner ports. This also provides for a cove under each coal that will glow red and create an attractive ember bed effect.
  • Page 42 THIS PAGE IS LEFT BLANK, INTENTIONALLY.
  • Page 43 THIS PAGE IS LEFT BLANK, INTENTIONALLY.
  • Page 44: Installation Check Off List

    INSTALLATION CHECK OFF LIST Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota approved person in accordance with instructions. All joints must be se- cured, "twist-locked" and leak-proof. 1000 F sealant must be used on the inner º...
  • Page 45: Lighting Instructions

    LIGHTING INSTRUCTIONS IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" (PG. 44) have been completed! CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before relighting - be sure to always remove the glass before relighting the pilot.
  • Page 46 13. Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in igni- tion or if flame is "lifting off" burner, turn off burner and carefully check for proper installation of logs/coals, vent system and proper pilot flame impingement on burner and thermopile.
  • Page 47: Thermostat Or Remote Control Operation

    60 seconds and repeat lighting procedure. If burner does not come on immediately after second try recheck complete installation. If necessary, contact your Mendota dealer. NOTE: If thermostat is located over 25 ft. from fireplace the pilot flame may need to be increased up to 750 millivolt.
  • Page 48: Blower Wiring Diagram

    BLOWER OPERATION The Mendota DXV Fireplace is designed so the blower operates at all times the fireplace is operating. The blower output can be regulated with the rheostat (included), but it must be "on" at all times the burner is "on". NOTE: There will be a time delay in blower operation during "heat-up"...
  • Page 49: Trouble Shooting Mendota Gas Dxv Fireplace

    If sooting continues open air shutter on burner (see "Gas Flame Adjustment" below). If sooting still continues, shut off unit and call Mendota service person. NOTE: To clean glass - remove glass and wipe glass with cloth or paper towel.
  • Page 50: Customer Information And Trouble-Shooting

    (usually a thin black film on the Fireplace viewing glass or on the outside of the home around the vent cap), the unit must be immediately turned off and the local Mendota dealer promptly informed.
  • Page 51: Maintenance

    "open". Clean the pilot and under side of the logs for any Carbon deposits. NOTE: Logs should be visually checked for Carbon "build-up". If carbon deposits are visible on logs, unit should be turned off and Mendota service person on PAGE contacted.
  • Page 52: Natural To Lp Gas Conversion

    NATURAL TO LP GAS CONVERSION HA-30-00325 This conversion must be made by a qualified service technician. ORIFICE SIZES REQUIREMENT: When the DXV35 employs the rear vent option, the rear burner orifice must be changed in an LPG configuration to a #61 Spud Orifice (supplied with the Fireplace). The front burner orifice remains unchanged at #55 for LPG applications.
  • Page 53 LP PRESSURE REGULATOR SCREWS GAS VALVE BODY NG PRESSURE REGULATOR Figure 16...
  • Page 54: Replacement Parts

    REPLACEMENT PARTS MENDOTA GAS DXV-35 FIREPLACE PART NO DESCRIPTION PART NO DESCRIPTION HA-29-00035 DOOR GASKET 05-04-00035 PILOT ASS'Y. NAT. 65-06-00463 GLASS – FLAT 05-04-00036 LP PILOT ORIFICE HA-30-00012 DOOR FRAME ASSEMBLY – FLAT 05-07-00067 THERMOCOUPLE 05-07-00061 THERMOPILE 65-06-00623 GLASS – BAY...
  • Page 55: Mendota Designer Fronts Installation Information

    MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION The following Designer Fronts are available for the DXV-35 Fireplace: 1. Andover, Bentley Arched Door Kit or Prairie Rectangular Door kit with Fire screen with optional Overlays as listed below: Black Overlay b. Pewter Overlay Antique Copper Overlay d.
  • Page 56 Faceplate with non-combustible materials such as Tile, Marble, Slate, Stone and Brick; as long as enough room is allowed for the removal of these Mendota Designer Fronts and the glass door for servicing, WARNING: COMBUSTIBLE MATERIALS MUST NOT COVER THE FRONT SURFACE OF THE FIREPLACE’S FACEPLATE.
  • Page 57: Label Representation

    " Label Representation" DXV35 LISTED DIRECT VENT GAS FIREPLACE HEATER POÊLE AU GAZ HOMOLOGUE’, A AÉRATION DIRECTE NOT FOR USE WITH SOLID FUEL (NE DOIT PASÉ UTILISÉ AVEC UN COMBUSIBLE SOLIDE) Manufactured by (Fabriqué par): JOHNSON GAS APPLIANCE CO. CEDAR RAPIDS, IOWA CERTIFIED FOR CANADA HOMOLOGUÉ...
  • Page 58: Mendota Warranty Qualification & Service Reference Form

    As a part of Mendota's on-going program of customer satisfaction, this Form verifies proper installation and operation. It is important as a reference for future service. It insures long life and trouble-free operation of Mendota fireplaces & stoves and qualifies the owner for Mendota's lifetime limited warranty.
  • Page 59 PLEASE REGISTER AT OUR WEBSITE AT: WWW.JOHNSONGAS.COM/MENDOTA-REGISTRATION.ASP...
  • Page 60 TAPE SHUT -------------------------------------------------------------------------------------------------------------------------------------------------------- POSTAGE NEEDED JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N.W. CEDAR RAPIDS, IA 52405...
  • Page 61: Mendota Extended Lifetime Protection And Limited Warranty

    The use of unauthorized components will make this warranty null and void. This warranty shall be effective only if the original purchaser of the Mendota appliance is registered with Mendota Division within thirty (30) days of the date of purchase. Such registration or the failure to register shall not be deemed to create any obligation or liability by the manufacturer and this warranty with its conditions and limitations shall be the only procedure for obtaining any rights against the manufacturer and expresses the sole obligation and respon- sibilities of the manufacturer which are offered to the original purchaser and accepted upon purchase of the appliance.
  • Page 62 Johnson Gas Appliance Company 520 E Avenue N.W. - Cedar Rapids, IA 52405 Mendota Hearth Division WEBPAGE: www.johnsongas.com www.mendotahearth.com Part #85-03-00700...