MENDOTA FV33-M GAS DIRECT VENT FIREPLACE INSERT
Minimum Fireplace Opening Required 
30‐3/8" wide X 18‐3/8" high X 15 3/4" Deep
30 3/8
22 3/16
16" MIN.
FROM GLASS FRAME EDGE
TO PERPENDICULAR SIDE WALL
-B-
VISIBLE GLASS SIZE = 398 SQ. IN.
ACTUAL GLASS SIZE = 468 SQ. IN.
29 3/16
SPECIFICATIONS & CLEARANCES
15 3/4
12" MIN
FROM TOP EDGE OF TOP
CONVECTION AIR OPENING
TO BOTTOM OF 8" DEEP MANTEL
18 1/16
HEARTH PROTECTION PAD REQUIRED IF NOT ELEVATED.
FOR EVERY 1-INCH THE UNIT IS ELEVATED, HEARTH
PROTECTION PAD DEPTH MAY BE REDUCED BY 2". IF ELEVATED
6" OR MORE, NO HEARTH PROTECTION PAD IS REQUIRED.
11
FV33-M Faceplate Dimensions
Inches
No Trim
24
Is available
27
For FV33-M
31
MANTEL DEPTH (IN.)
12
11
10
9
8
7
6
5
4
FIREPLACE FACE MUST BE COVERED W/
NONCOMBUSTIBLE FACING IN THIS AREA.
A COMBUSTIBLE MANTEL ONLY ALLOWED IN
THIS AREA IF INSTALLED OVER
0
NON-COMBUSTIBLE FACING MATERIAL.
8.0
APPROVED
MANTEL
PROFILES
1
1
4" NON
COMBUSTIBLE
16"
A
B
mm.
Inches
mm.
610
36
686
40
1016
788
44
1118
915

Advertisement