Rear Flue Venting Requirements - Mendota DXV-35 DEEP TIMBER II Installation & Operating Instructions Manual

Gas direct vent fireplace with hearthglo sealed combustion system
Table of Contents

Advertisement

NOTE
: A 9" MAXIMUM HORIZONTAL PIPE SECTION CAN BE USED WHEN VENTING THE DXV35 USING THE REAR
VENT OPTION AGAINST A FLAT EXTERIOR WALL or IN AN EXTERIOR CORNER.
MENDOTA RECOMMENDS THE USE OF DURAVENT 5"X8" COAXIAL PIPES AND FITTINGS.
COMPONENTS PROVIDE THE MOST FLEXIBILITY SINCE DURAVENT HORIZONTAL TERMINATION CAPS SLIDE
FULLY OVER THE 6" OR 9" STRAIGHT PIPE SECTION USED.
49 1/2" MIN.
CLEARANCE TO
COMBUSTIBLE
ABOVE UNIT
CEILING HEIGHT

REAR FLUE VENTING REQUIREMENTS

1
2
8" MANTEL
DEPTH (WIDTH)
14" DISTANCE
MINIMUM TO
8" MANTEL
& MINIMUM
NON-COMBUSTIBLE
HEARTH PROTECTION REQ'D.
SEE DESIGNER FRONTS
INSTALLATION INFORMATION
SECTION OF THIS MANUAL.
FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR, THE HEARTH
PROTECTION PAD MAY BE REDUCED BY 2".
SEE "MENDOTA DESIGNER FRONTS INSTALLATION INFORMATION SECTION
OF THIS MANUAL FOR SPECIFIC REQUIREMENTS FOR HEARTH PROTECTOR
PAD WHEN INSTALLING VARIOUS DESIGNER FRONTS
Figure 9: DXV35 Rear Horizontal Venting Requirements
WARNING
MUST REMAIN IN THIS
COMBUSTIBLE MANTEL
TRIANGULAR AREA. FOR
EVERY 1" INCREASE IN
MANTEL DEPTH, INCREASE
BY 2". MANTEL MAY BE LOWERED
DECREASED IN THE SAME MANNER
12"
A
DEPTH
24
HEIGHT ABOVE GRILL
IF DEPTH IS
8" THIMBLE
& 5"X8"
HORIZONTAL
TERMINATION
CAP
5"X8" PIPE
9" MAX.
DURAVENT
22-5/8"