EXTERIOR VENT LOCATIONS AND RESTRICTIONS

∨ -
Vent Terminal
A =
Clearance above grade, veranda, porch, deck, or balco-
ny (*12 inches (30 cm) minimum). Vinyl surfaces re-
quire 24" min.
B =
Clearance to window or door that may be opened
(*12 inches (30 cm) minimum.
C =
Clearance to permanently closed window (minimum 12
inches (30 cm) recommended to prevent condensation
on window)
D =
Vertical clearance to ventilated soffit located above the
terminal from the center-line of the terminal (12 inches
(30 cm) minimum) Vinyl surfaces require 24" min.
E =
Clearance to unventilated soffit (18 inches (46 cm)
minimum) Vinyl surfaces require 24" min.
F =
Clearance to outside corner - 6 inches (15 cm).
G =
Clearance to inside corner - 12 inches (30 cm). Vinyl
surfaces require 24" min.
† A vent shall not terminate directly above a sidewalk or paved driveway, which is located between two single-family
dwellings and serves both dwellings.
‡ Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* As specified in CGA B1:19 Installation Codes (1991). Note: Local codes or regulations may require different clearances.
Figure 2: Exterior Vent Locations
ALL MEASUREMENTS FROM CENTER LINE OF VENT CAP
∧ -
Air Supply Inlet
≡ -
Area where terminal is not permitted
H =
*Not to be installed above a meter/regulator assembly
within 3 feet (90 cm) horizontally from the center-line of
the regulator
I =
Clearance to service regulator vent outlet (*6 feet (1.8m)
minimum)
J =
Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other appliance.
*12 inches (30 cm) minimum.
K =
Clearance to a mechanical air supply inlet (*6 feet (1.8 m)
minimum)
L =
† Clearance above paved side-walk or a paved driveway
located on public property (*7 feet (2.1 m) minimum)
M =
Clearance under veranda, porch, deck, or balcony (*18
inches (30 cm) minimum ‡)
N=
Minimum 24" horizontal clearance to any surface, such as
an exterior surface, for vertical terminations.
8