MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
SPECIFICATIONS & CLEARANCES
WARNING: Do not cover the 2" faceplate border of the unit with combustible materials.
Figure 4: Specifications & Clearances
NOTE: For L.P. & High Altitude (above 4,000 ft. but below 7500 ft.), 45º elbows must be used in place of 90º elbows.
For Installation At Altitudes Above 7,500 Feet, First Call Mendota Technical Hotline For Further Information On The Strict
Requirements For Installations At These Altitudes.
CAUTION: If 90ºelbows must be used with LP or at high altitudes, a 2-foot vertical starter section must be used
directly off the top of the fireplace.
17