L.P. GAS MINIMUM HEIGHT HORIZONTAL TERMINATION
L.P. G
AS OR
WALL THIMBLE
6" COAX VENT
45° COAX VENT
45° COAX VENT
9" COAX VENT
For L.P. gas and high altitude installations (above 4,000 ft.), 45° elbows must be used in place of 90° elbows.
CAUTION: If 90° elbows must be used, a 3-foot vertical starter section must be used off the top of the fireplace.
H
A
(
IGH
LTITUDE
REQUIRED
(MIN.)
(MIN.)
85-03-00531
15 1/2"
NOTE: This requires 19" minimum height to center.
4,000
. BUT BELOW 7500 FT.)
ABOVE
FT
TERMINATION CAP
19"
(MIN.)
15
46 1/4"
(MIN.)