Building Permit And Installation Inspection Approval Requirements - Mendota DXV-35 DEEP TIMBER II Installation & Operating Instructions Manual

Gas direct vent fireplace with hearthglo sealed combustion system
Table of Contents

Advertisement

BTUH. (MODEL DXV-35)
BTUH. (MODEL DXV-35)
NOTE: LP CONVERSION KIT #HA-30-00325 MUST BE PURCHASED SEPARATELY TO BURN LPG.
MAIN ORIFICE...i.) TOP VENT: REAR BURNER: #52 NAT. GAS [#59 L.P. GAS] – FRONT BURNER: #42 NAT. [#55 LP]
ii.) REAR VENT: REAR BURNER: #53 NAT. GAS [#61 L.P. GAS] – FRONT BURNER: #42 NAT. [#55 LP]
OVERALL EFFICIENCY
CO-AXIAL DIRECT VENT FLUE ..... TOP VENT: 4" INNER, 6 5/8" OUTER; REAR: 5" INNER 8" OUTER
TOTAL WEIGHT ................................. 185 POUNDS
SAFETY ................................................ AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
GAS REQUIREMENTS ........................ SUPPLY PRESSURE:
ELECTRICAL REQUIREMENTS ....... 115 VOLT, LESS THAN 2 amps
APPROVED VENT SYSTEMS: AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to floor
Unit to enclosure sidewall
Vent to enclosed
Vent to adjacent sidewall
Certified under ANSI Z21.88 (2002)
for bedroom installations and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recrea-
tional vehicles."
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National Stan-
dards Institute - ANSI Gas Appliance Safety Standards
The Mendota Gas DXV Fireplace has been tested and certified by Intertek Testing Services 8431 Murphy Drive, Middleton, WI
FIREPLACE INCLUDES A HEARTHGLO SEALED COMBUSTION SYSTEM, 6-PIECE CERAMIC FIBER LOG SET &
COALS, FIREBRICK LINED FIREBOX, NEO-CERAM GLASS, PIEZO IGNITER, DUAL BLOWERS, AGA CERTIFIED
SAFETY SYSTEM, and WALL THERMOSTAT.
OPTIONS: DIRECT REAR VENT KITS, BLACK, BRASS, CLASSIC BRASS OR CLASSIC SILVER TONE GRILL SETS,
BLACK OR 24K GOLD "VICTORIA" & "TUSCANY" FILIGREE FRONTS, ANDOVER ARCHED DOORS & 4 COLOR
OVERLAY FRONTS, PRAIRIE RECTANGULAR DOORS & 4 COLOR OVERLAY FRONTS, DEERFIELD FRONT,
WELLINGTON FRONT, VERSIHEAT REMOTE FORCED AIR HEAT TRANSFER SYSTEM.

Building Permit and Installation Inspection Approval Requirements

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER.
SPECIFICATIONS
MODEL DXV-35
High Fire - Adjustable to - Low Fire
NAT. GAS
33,000
LP GAS
33,000
EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.) FOR DIRECT VENT
WALL HEATERS
ACTIVATED WITH SWITCH, THERMOSTAT OR REMOTE CONTROL.
NAT. GAS:
7" W.C. (5" W.C. MIN., 11" W.C. MAX.)
L.P. GAS:
11.0" W.C. (11" W.C. MIN., 13" W.C. MAX.)
0 in.
0.5 in.
1 in.
10 in.
CSA 2-33 (2002) "Vented Gas Fireplace Heaters" not for use with solid fuel. Approved
All installations of Mendota Fireplaces and Inserts must comply with all the re-
quirements stated in this Installation and Operating Instructions Manual. The
Dealer and/or installer must also obtain all required Building Permits and Inspec-
tion Approval from the local building inspection department or the local body
having jurisdiction. In order to validate warranty coverage, Mendota may re-
quire facsimile copies of the Building Permit and Inspection Approval forms.
Failure to provide adequate proof that the installation conforms to all local re-
quirements and the requirements stated in the Installation and Operating Instruc-
tions Manual will void all applicable warranty.
13,400
14,200
GAS INLET: 3/8" N.P.T.
Unit to enclosure sidewalls
Unit top to ceiling
Wall Pass-Through to framing
Mantle above discharge air opening 14 in.
2
0.5 in.
18 in.
1 in.