Mendota DXV-35 DEEP TIMBER II Installation & Operating Instructions Manual page 46

Gas direct vent fireplace with hearthglo sealed combustion system
Table of Contents

Advertisement

13. Main burner should now light IMMEDIATELY and flame should not "lift" off burner. If there is any delay in igni-
tion or if flame is "lifting off" burner, turn off burner and carefully check for proper installation of logs/coals, vent
system and proper pilot flame impingement on burner and thermopile. Logs or coals must not block pilot flame or
main burner flame. Vent system must be leak proof.
DO NOT PROCEED WITH OPERATION UNLESS BURNER "CYCLES" ON/OFF WITHOUT DELAYS!
14. To reduce heat output, turn Hi/Lo Knob counterclockwise to desired temperature (see FIGURE 10: Gas Valve).
Heat output can be reduced to 23,000 BTUH using the Hi-Lo Control. NEVER "over fire" by increasing BTUH
above nameplate specifications. NEVER turn down (reduce) pilot flame below the minimum 325 millivolts.
15. To reduce the flame and heat down to 6500 BTUH., use the rocker switch (see step 7) to turn off rear burner.
NOTE: The rear burner is controlled by a 9 Volt DC solenoid valve. One 9 Volt cell battery (located behind the
control panel) provides power for this unique feature. Replace with a new high quality 9 Volt battery annually.
16. Open windows for first two hours of operation.
NOTICE: Initial heater start-up will cause some NON TOXIC "off gassing" of adhesives, gasket binders, paint and other materials. Most
nuisance odors will be eliminated after the first two hours of operation; however, slight amounts may be present during first 24 hours of
. To eliminate all nuisance odors, continuously operate this fireplace on the HIGH setting for 8 to 12
initial operation
hours.
SHUT DOWN PROCEDURE:
1. Turn Remote Control or Thermostat to "OFF". Pilot will remain lit for return to normal service.
2. For complete shutdown turn Gas Cock Dial to "OFF".
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
45

Advertisement

Table of Contents
loading

Table of Contents