Dead Machine Service Check

Note: Check the AC line voltage. The voltage should be within the
following limits:
100 V ac – 127 V ac for the low voltage model printer
200 V ac – 240 V ac for the high voltage model printer
FRU
Low Voltage Power Supply Fuse
(LVPS)
Power Switch
27 V ac for the low voltage model printer
Fuse
Action
Check the fuse on the LVPS board
for continuity.
• If open, replace with appropriate
fuse.
– If fuse opens again, see
Voltage Power Supply (LVPS)
Service Check" on
page
2-44.
• If not open, see power switch
below.
Turn on the printer power switch.
Check for ac line voltage in the
switch cable, CN1 (LVPS board),
between pin 1 and ground and
between pin3 and ground.
• If line voltage is present, see the
"Cover Interlock Switch" on
page
2-40.
• If line voltage is not present on
CN1, replace the power switch or
check/correct missing line voltage.
missing line voltage.
Diagnostic Information
"Low
2-43