Solid State Logic AWS 900+ Owner's Manual page 142

Analogue workstation system
Hide thumbs Also See for AWS 900+:
Table of Contents

Advertisement

Link Options
There are a number of internal link options that may require adjustment. Refer to page A-14, 15 for information
on accessing the relevant PCB.
629653X1/2 S/A GAIN & MDAC CONTROL / TB & LISTEN
Link
Position
LK6
Fitted
LK1
A
B
C
LK2
1-2 (Left)
2-3 (Right)
LK3
A
B
LK4/5
1-2 (Right)
2-3 (Left)
629653X2 only
LK10*
1-2
2-3
*Use in conjunction with LK12 on 629654X2 card
629654X1/2 S/A MON OUTPUTS
Link
Position
LK7
Fitted
LK1/2
A
B
LK3/4
A
B
LK5/6
A
B
LK8/10
A
B
LK9/11
A
B
629654X2 only
LK12*
Fitted
Not fitted
*Use in conjunction with LK10 on 629653X2 card
Default
Function
0V to 0VA
Ext TB Mic input has 48V phantom power
-
Ext TB Mic input has no phantom power
-
Ext TB Mic has 1.5V phantom (for electret microphones)
Ext TB Input balanced
-
Ext TB Input pin 3 grounded (for use with electret mic)
Listen Mic input has 48V phantom power
-
Listen Mic input has no phantom power
-
LFE 80Hz hi-pass filter rolls off at 12dB/octave
LFE 80Hz hi-pass filter rolls off at 24dB/octave
Surround feeds LFE when Bass Management is On
Surround does not feed LFE
Default
Function
0V to 0VA
Left 80Hz lo-pass filter rolls off at 12dB/octave
-
Left 80Hz lo-pass filter rolls off at 24dB/octave
Right 80Hz lo-pass filter rolls off at 12dB/octave
-
Right 80Hz lo-pass filter rolls off at 24dB/octave
Centre 80Hz lo-pass filter rolls off at 12dB/octave
-
Centre 80Hz lo-pass filter rolls off at 24dB/octave
Left Surround 80Hz lo-pass filter rolls off at 12dB/octave
-
Left Surround 80Hz lo-pass filter rolls off at 24dB/octave
Right Surround 80Hz lo-pass filter rolls off at 12dB/octave
-
Right Surround 80Hz lo-pass filter rolls off at 24dB/octave
Bass management switches Hi Pass filters in to surround
Surround Hi Pass filters disabled
Environmental Specification
AWS 900+ Owner's Manual
A - 1 9

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AWS 900+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents