Glide Frames - Sets the ramp time in frames for Snap mode. The range is from 0 (no glide) to 255 (10 second
glide).
Rollback Threshold frames - Sets the number of consecutive descending frames that the systems needs to see
to determine if a rollback has taken place. The range is 2-10 and the default is 2 frames. Increase as required if
a rollback occurs on stopping the timecode master.
Latched Match & Play - Normally Match and Play are automatically deselected after a Cut switch is operated.
This option latches the Match or Play function until deselected manually.
00: 02: 12: 23 M i x Enabl ed
Glide frames: 10
Rollback Threshold frames: 5
Latched Match and Play: No