15.1.2 ACAI manual mode

• During the manual ACAI procedure the reference weight will only be re-calculated
after pressing the ENTER key.
• Setting in menu (chpt..14.2): F-02-01 = „2"
1. Run:
Leave the piece number on the weigh-
ing plate after setting the reference
weight
2. Add additional pieces within the next
ACAI range (see table in test passage
above). The triangle
above "AUTO OPTIM." ) as soon as
the weight is within the ACAI range.
3. Wait until the display is stable, then
press the ENTER key. During the cal-
culation of the new reference weight
the triangle
(above "AUTO OPTIM.)
will be flashing for a moment and then
disappear.
4. Add more pieces within the ACAI range until you have reached a piece number
that is as great as the greatest piece number you wish to count.
5. When you have added the maximum number of required pieces, remove the
pieces and start the add-up procedure.
CWS-BA-e-0610
will pop up (
21
111.000
2.331
Kg
g
43