KERN CWS Operating Instruction page 39

Counting scale
Table of Contents

Advertisement

F-06-X RS-232C Data output
Function
Parameter
selection
key
Data output mode
0*
1
2
3
F-06-01
4
5
6
7
8
* "close to ZERO" means between -4d and +4d of weight data
Selection of output values
0100*
ID
reference weight
F-06-02
0 0 0 0
Weight
Quantity
Data format
0*
F-06-03
1
2
Baud rate
0*
F-06-04
1
2
Data length and parity
0*
F-06-05
1
2
Information: Use the setting "0" at all times for F-07 and F-08
CWS-BA-e-0610
Data are transmitted by pressing the PRINT key.
+ remote control instructions
Continuous data transmission
It is not possible to use remote control commands
Data will be transmitted when the weight display is stable at +5d or
above.
+ remote control instructions
Data will be transmitted when the weight display is stable at 5d or
above/below.
+ remote control instructions
Remote control commands only
Not documented
Not documented
Not documented
Not documented
Transmitting data
To select which data to transmit, enter either "0" or "1" for the
data: ID no., piece number, weight or reference weight
Example: When "1100" is entered only the ID no. and the
piece number will be sent.
Not documented
Not documented
Format for general peripherals
2400 bps.
4800 bps.
9600 bps.
7 Bit, even parity
7 Bit, odd parity
8 Bit, no parity
Description of function
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents