Sign In
Upload
Manuals
Brands
KERN Manuals
Scales
TACJ
KERN TACJ Manuals
Manuals and User Guides for KERN TACJ. We have
1
KERN TACJ manual available for free PDF download: Service Manual
KERN TACJ Service Manual (61 pages)
Analytical balance
Brand:
KERN
| Category:
Scales
| Size: 2.75 MB
Table of Contents
Table of Contents
3
1 Operations for Adjustment
5
Entering the Service Mode
5
Contents of Service Menu
6
Service Mode Functions
7
2 Disassembling and Assembling the Balance
10
Precautions
10
Inspecting the Balance Interior (Removing the Case and Pan Supporter)
12
Replacing Components
15
Replacing the Front Glass ASSY (C8)
15
Replacing the Side Glass ASSY (C6, C7)
16
Replacing the Roof Glass ASSY (C5)
16
Replacing the Display Board ASSY (B2)
16
Replacing the Power Board ASSY (B4)
17
Replacing the Analog Board ASSY (B3)
18
Replacing the Weight Loader ASSY (27)
19
Replacing the Unit ASSY (1)
20
Replacing the Detector ASSY (U11)
21
Replacing the Force Coil ASSY (L1)
22
Replacing the Stopper Plate (U14)
25
Replacing the Stopper Lever (U15)
25
3 Checking the Electronic Board
27
Display Board ASSY (B2)
27
Analog Board ASSY (B3)
28
Preamp Board ASSY (B1)
28
Power Board ASSY (B4)
29
4 Hardware Adjustment
30
Adjusting the Detector ASSY (U11) Height
30
Adjusting the Tilt Error
31
Adjusting the Balance
32
Adjusting the Cornerload Error
33
5 Software Adjustment
35
EEPROM Initialization
35
Model Selection
36
Releasing and Setting the Setting Information Lock
36
Releasing the Setting Information Lock
37
Setting the Setting Information Lock
37
Inputting Weight Values for Linearity Adjustment
38
Linearity Adjustment
38
Internal Weight Calibration (PCAL) (ACJ Only)
39
Operation Procedure and Process
39
Sensitivity Calibration
42
Menu Settings „I.CAL" / „E.CAL
42
Adjustment with External Weight (KERN ACS)
43
Adjustment with Internal Weight (KERN ACJ)
44
Weight Loader Mechanism Operation Check
45
Operation Procedure and Process
46
Errors
46
6 Eeprom
47
PRINT Operations
47
Data Edit (EDIT) Operations
48
Backup (BKUP) Operations
48
Download (RESTR) Operations
49
All Initialization (INIT) Operations
49
7 Performance Inspection
50
Reproducibility
50
Cornerload Error
50
Linearity
51
Tilt Error
51
8 Problems and Solutions
53
General Problem Solutions
53
Error Display
55
User Mode Errors
55
Service Mode Errors
56
9 Troubleshooting
57
Display Won't Appear
57
Key Operation Does Not Work
57
ERR C" Is Displayed
58
ERR H" Is Displayed
60
When Power Is Switched On, Display Stops at "Software Version
60
Trouble of Weight Loader
61
Advertisement
Advertisement
Related Products
KERN TAB
KERN TALJG-A
KERN TALSG-A
KERN TALSG 160-4-A
KERN TALSG 250-4-A
KERN TALJG 160-4-A
KERN TADJ 220-4-B
KERN TALJ-A02-A
KERN TABP-A02-A
KERN TACS
KERN Categories
Scales
Measuring Instruments
Microscope
Monitor
Camera Accessories
More KERN Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL