N700E INSTRUCTION MANUAL
PID Disable [PIDD]
• When the terminal [PID Disable] is turned on, the inverter operates without PID control. Setting the function
code F01 can change the target frequency.
When the terminal [PID Disable] is turned off, the inverter operates with PID control.
Option
Terminal
Code
Symbol
23
PIDD
Valid for inputs:
Required setting
Notes:
•The PID Disable [PIDD] is valid only when the
PID controller is enabled.
• When the PIDD terminal is turned on, frequency
command is changed to the Function code F01.
RUN command
[FW,RV]
[PIDO] terminal
Output frequency
[d01]
Input
Function Name
State
ON
PID Disable
OFF
C01,C02,C03,C04,C05,C06
F01,A01,A70=01 or 02
ON
ON
OFF
Target frequency
[F01]
PID controller is off.(PID Disable)
PID controller is on.(PID Enable)
Example:
CM1
6
5-20
ON
Description
PIDD
5
4
3
2
1
P24