Hyundai N700E Instruction Manual page 72

Hide thumbs Also See for N700E:
Table of Contents

Advertisement

N700E INSTRUCTION MANUAL
Multi-Speed Select [CF1][CF2][CF3][CF4]
• The inverter provides storage parameters for up to 16 different target frequencies (speeds) that
the motor output uses for steady-state run condition.
These speeds are accessible through programming four of the intelligent terminals as binary-encoded
inputs CF1 to CF4 per the table .
These can be any of the six inputs, and in any order.
You can use fewer inputs if you need eight or less speeds.
Note : When choosing a subset of speeds to use, always start at the top of the table, and with the
least-significant bit: CF1, CF2, etc.
NOTE : Speed 0 is set by the
Multi-speed
SW5
Speed 0
OFF
Speed 1
OFF
Speed 2
OFF
Speed 3
OFF
Speed 4
OFF
Speed 5
OFF
Speed 6
OFF
Speed 7
OFF
Speed 8
ON
Speed 9
ON
Speed 10
ON
Speed 11
ON
Speed 12
ON
Speed 13
ON
Speed 14
ON
Speed 15
ON
F01 parameter value.
Control circuit terminal
SW4
SW3
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
5-5
SW2
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents