Output Power Versus Ambient Temperature
Once the heat sink on the inverter reaches a maximum temperature limit, the GT Inverter
reduces its energy output to ensure component ratings are not exceeded.
Environmental Specifications
User Display
Display Accuracy
975-0334-01-01
Output Power vs Ambient Temperature
Vin = 550 Vdc, Vout = 240/208 Vac
6
5
4
3
2
1
0
20
30
Figure A-7 Output Power vs. Ambient Temperature
Operating temperature range
Storage temperature range
Power derating
Tolerable relative humidity limit
Type
Size
Instantaneous Power
Voltage
Current
System Lifetime energy
Output Power Versus Ambient Temperature
40
50
Temperature (C)
-25° to +65° C (-13° to +149° F)
-40° to +85° C (-40° to +185° F)
See Figure A-7 on page A–11
Operating: <95%, non-condensing
Storage: 100% condensing
alphanumeric liquid crystal display with backlight
2 lines by 16 characters
+/- (30 W + 1% of reading)
+/- (1% of rating + 1% of reading)
+/- (1% of rating + 1% of reading)
+/- 5%
5kW-240V
5kW-208V
4kW-240V
4kW-208V
3.3kW-240V
3.3kW-208V
2.8kW-240V
2.8kW-208V
60
70
A–11