Step 5: Connecting AC Output to an
Existing AC Circuit
ELECTRIC SHOCK AND FIRE HAZARDS
Make sure wiring is disconnected from all electrical sources
n
before handling. All wiring must be done in accordance with
local and national electrical wiring codes.
A manufacturer-tested and approved RCBO (Type B) must
n
be connected to the Freedom X AC output and RCBO
protection must be provided on every branch circuit feeding a
receptacle connected to the AC hard wired installation, if
local regulations require it.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
26
WARNING
NOTICE
EQUIPMENT DAMAGE
Do not connect any AC source (such as a generator or
n
utility power) to the AC output wiring of the Freedom X.
The Freedom X will not operate if its output is connected
n
to AC voltage from a source, and potentially hazardous or
damaging conditions may occur. These conditions can
occur even if the inverter is off.
Failure to follow these instructions can result in equipment
damage.
Do not connect the Freedom X to an AC branch circuit that has
high-power consumption loads that exceed its output wattage
rating.
The Freedom X will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than
its rated output wattage.
Freedom X 2000 - 230V Owner's Guide