Basic Installation Procedures

Step 5: Connecting AC Output to an Existing AC Circuit

WARNING
FIRE, SHOCK, AND ENERGY HAZARDS
Make sure wiring is disconnected from all electrical sources before
handling. All wiring must be done in accordance with local and national
electrical wiring codes.
Failure to follow these instructions can result in death or serious injury.
EQUIPMENT DAMAGE
Do not connect any AC source (such as a generator or utility power) to
the AC wiring output of the Freedom Xi.
The Freedom Xi will not operate if its output is connected to AC voltage
from another source, and potentially hazardous or damaging conditions
may occur. These conditions can occur even if the inverter is off.
Failure to follow these instructions can damage the unit and/or equipment.
Do not connect the Freedom Xi to an AC branch circuit that has
high-power consumption loads.
The Freedom Xi will not operate electric heaters, air conditioners,
stoves, and other electrical appliances that consume more than 1000
watts (Freedom Xi 1000 models) or 2000 watts (Freedom Xi 2000
models).
18
NOTICE
A manufacturer-tested and approved GFCI must be connected to the
Freedom Xi AC output, and on every receptacle connected to the
AC hard wired installation. Other types may fail to operate properly
when connected to the Freedom Xi. Although you can reuse the
factory-installed GFCI, the manufacturer has also tested and
approved the following GFCIs for use with the Freedom Xi inverter.
See "Ground Fault Circuit Interrupters (GFCIs)" on page 11.