IMAGE ADJUSTMENTS
3.19.3 REGISTRATION
Image Area
B
The image area must be configured
Feed direction
correctly. Adjust the registration within
the adjustment standard range as
A
described below.
Image Area
C
B146R966.WMF
A = B = C = 4.2 mm (1.6")
Leading Edge
Adjusts the leading edge registration for each paper type and process line speed.
Side to Side
Adjusts the side-to-side registration for each paper feed station. The side-to-side
registration for the LCT can be adjusted with SP1002 006.
Adjustment Standards
• Leading edge (sub-scan direction): 3 ± 0 mm
• Side to side (main-scan direction): 2 ± 0 mm
Paper Registration Standard
The registration in both main- and sub-scan directions may fluctuate within the
following tolerance.
1st side
• Sub-scan direction: 0 ± 1.5 mm
• Main-scan direction: 0 ± 2 mm
2nd side in duplex
• Sub-scan direction: 0 ± 3 mm
Main-scan direction:
0 ± 4 mm
SM
3-177
B132/B200