1202 Set Fusing Temp
This SP sets the time interval for the machine to remain idle to trigger lower power
mode 1.
Set Fusing Temp
001 EngSave Time 1
002 EngSave Time 2
003 EngSave Time 3
Heating Roller
004 Energy Save 1
005 Energy Save 2
006 Energy Save 3
Pressure Roller
007 Energy Save 1
008 Energy Save 2
009 Energy Save 3
Hot Roller
010 Energy Save 1
011 Energy Save 2
012 Energy Save 3
1203
Fusing:I/O
This SP adjusts the operation of the fusing exit sensor.
001
FuseExitSn:On/Off
002
FuseExitSn Timing
003
FuseExitSn ON
004
FuseExitSn Disp
005
FuseExit M ON
1901
CPM Down:Thk
This SP adjusts the CPM down time for thick paper and tab sheets.
001
CPM Down:Thk
002
CPM Down:Tab
SM
Set Fusing Temperature (for shift to low power mode)
[0~60/1 deg.]
Fusing Input/Output
Display indicates whether the fusing exit sensor is on or off.
0: OFF 1:ON
Displays the time interval from when the registration motor
goes off to when it restarts.
[0~5000/1 msec.]
Display indicates whether the fusing paper remains sensor is
on or off.
[0~5000/1 msec.]
Dsiplays whether the paper remains sensor is on or off from
when the registration motor goes off until it restarts.
0: OFF 1:ON
Switches forced rotation of the fusing/exit motor on/off.
[0~1/1]
CPM Down Mode: Thick Paper
Special CPM Down Setting: Thick Paper
[0~4/1]
Special CPM Down Setting: Index Tabs
[0~4/1]
5-31
SERVICE PROGRAM TABLES
B132/B200