3820 Manual ProCon
Use this SP to execute process control manually.
3820 001 does potential control only.
3820 002 does potential control and toner density adjustment.
Note:
•
You must do SP3820 to enable any values you change with SP3531 (Procon
Target).
•
Use SP3561 to display the resuls of SP3820 execution.
001 Normal ProCon
002 Exe Density Adj
3821 ProCon OK?
Use this SP to display the history of process control executions. These SP codes are
used to troubleshoot processing control. For more, see "4.2 Process Control
Troubleshooting" in Section "4. Troubleshooting".
[0~99999999/1]
001 History:Last
002 History:Last 2
003 History:Last 3
004 History:Last 4
005 History:Last 5
3891 Set ProCon Send
This feature is not presently used. (March 2005)
[0~1/1]
3900 RsetProConSP
Do this SP to reset all process control related SP codes to their default values.
SM
Execute Process Control Manually
[0~0/1]
Display Result of Process Control Execution
006 History:Last 6
007 History:Last 7
008 History:Last 8
009 History:Last 9
010 History:Last 10
Set Up Sending Process Control Data to NRS Center
Reset All Process Control SP Codes
5-95
SERVICE PROGRAM TABLES
B132/B200