030 CMY:LowMin.
031 CMY:MidMin.
032 Base MaxDiff
033 Patch Mini Gap
034 Light Target Adj
035 MY Light Max
036 Add Upper Limit
037 Add Lower Limit
038 LaserX:FrontXf
039 LaserX:CenterXc
040 LaserX: RearXr
041 LaserX: TempCoeff
2154
2-Point Target
These 2-point target settings done at the factory affect the characteristics of the
lenses. These target values must be entered when when the laser unit is replaced.
The correct settings are printed below the first barcode on one A5 sheet of paper
provided with the replacement laser unit.
001 K
[60700~63230/61984/1]
002 M
003 C
004 Y
2155
2-Point Int Set
These SPs adjust the difference in the position of color registration for MUSIC in
the main scan direction, using K (black) as the reference point.
Do SP2109 002 and print Pattern 1 on A3 size paper. Examine the pattern with a
scaled lupe. For every 43.2µm adjust the setting in the left or right direction. A 1
step correction corrects 50µm. For more, please refer to Section "3.
Replacement and Adjustment".
001 M Main Scan
002 C Main Scan
003 Y Main Scan
SM
No information is available at this time.
[0~50/0.1V]
No information is available at this time.
[0~50/0.1V]
No information is available at this time.
[0~50/0.1V]
No information is available at this time.
[0~50/0.1V]
Sets the target value for the intensity of the MUSIC sensor
lights.
[0~50/0.1V]
Sets the maximum value for the intensity of the MUSIC
sensor lights.
[0~255/0.1V]
No information is available at this time.
2-Point Interval Target Setting
2-Point Interval Target Setting DFU
[-5~+5/1 (43.2µm)
5-39
SERVICE PROGRAM TABLES
B132/B200

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B200

Table of Contents