B132/B200; Installation; Installation Requirements; Operating Environment - Ricoh B132 Service Manual

Table of Contents

Advertisement

1. INSTALLATION

1.1 INSTALLATION REQUIREMENTS

1.1.1 OPERATING ENVIRONMENT

1. Temperature Range:
2. Humidity Range:
3. Ambient Illumination:
4. Ventilation:
5. Ambient Dust:
1
*
If the machine is installed in a location where the ambient temperature is more
o
o
that 30
C (86
F):
• Do not run full color copying longer than 2 hours.
• Never turn the main power switch off immediately after a long copy job.
Leave the machine on so the fans can expel the hot air from the machine
and cool the electronic components.
Temperature and Humidity for Operation
% R h
90
80
70
60
50
40
30
20
10
0
Recommended Temp., Humidity: 23°C (73.4°F) 50% Rh
SM
Recommended Temp.: 23°C (73.4°)
Allowed Temp.: 10°C to 32°C (50°F to 90°F) *
15% to 80% Rh
Less than 1,500 lux (do not expose to direct sunlight or
strong light.)
Air must be replaced a minimum of 3 times per hour
Less than 0.10 mg/m
Allowed Range
25C (77F) 70% R h
Office
15C (59F) 30% R h
10C (50F) 15% R h
20
10
1-1
INSTALLATION REQUIREMENTS
3
27C (80.6F) 80% R h
32C (89.6F) 54% R h
o
C
30
B132I900.WMF