Adf Output Check: Sp6008 - Ricoh B132 Service Manual

Table of Contents

Advertisement

5.7.2 ADF OUTPUT CHECK: SP6008

1. Open SP mode SP6008.
2. Select the SP number that corresponds to the component you wish to check.
(Refer to the table below.)
3. Press On then press Off to test the selected item. You cannot exit and close
this display until you click Off to switch off the output check currently executing.
6008
ADF Output Chk
Turns on the ADF electrical components individually for testing. Select the
component to test, then touch the "ON" button. Besure to touch the "OFF" button
as soon as you hear the component turn on.
001 ADF Feed M:Fwd
002 ADF Feed M:Rev
003 ADF Trans M:Fwd
004 ADF Ext M:Fwd
005 ADF Top Inv M:Fwd
006 ADF Top Inv M:Rev
SM
ADF Output Check
007 ADF Bot Inv M:Fwd
008 ADF Bot Inv M:Rev
009 ADF Pickup M:Fwd
010 ADF BotPlt M:Rev
011 ADF Top Inv SOL
012 ADF Bot Inv SOL
5-201
ARDF INPUT/OUTPUT CHECK
B132/B200