SERVICE PROGRAM TABLES
1200 1st CMP Down
This SP adjusts the temperature of the heating roller at the start of the CMP down
modes for black-and-white copying in normal/high temperature environments.
1st CPM Down
001
StrTemp:Low/Hi:1C
002
StrTemp:Low/Hi:FC
003
StrTemp:Low:1C
004
StrTemp:Low:FC
005
CPM Norm/Hi:1C
006
CPM Norm/Hi:FC
007
CPM Low Temp:1C
008
CPM Low Temp:FC
2nd CPM Down
009
CPM Norm/Hi:1C
010
CPM Norm/Hi:FC
011
CPM Low:1C
012
CPM Low:FC
3rd CPM Down:Thk
013
1C:60/45/30cpm
014
FC:45/25/15cpm
015
(0:Yes 1:No)
1201 HtgRoll L2:Hys
This SP adjusts the control temperature of the heating roller when Lamp 2 in the
heating roller is switched on.
001 On
002 Off
B132/B200
1st CMP Down (Heating Roller Temperature)
Normal temperature, high temperature environment
[–20~0/1 deg.]
Low temperature environment
[–20~0/1 deg.]
Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
Low temperature environment, A4 SEF
[10~60/5 cpm]
Low temperature environment, A4 SEF
[10~60/5 cpm]
2nd CPM Down
Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
Normal, high temperature environment, A4 SEF
[10~60/5 cpm]
Low temperature environment, A4 SEF
[10~60/5 cpm]
Low temperature environment, A4 SEF
[10~60/5 cpm]
3rd CPM Down: Thick Paper
CPM down settings (based on A4 SEF) for black and white.
[0~4/1]
0:60 cpm 1:50 cpm 2:45 cpm 3:30 cpm)
CPM down settings (based on A4 SEF) for full color.
[0~4/1]
0:60 cpm 1:50 cpm 2:45 cpm 3:30 cpm)
Switches the CPM down feature on/off
0:OFF 1:ON
Heating Roller 2: Hysterisis On/Off
[-5.-~+5.0/0.5]
Note: Every "0.1" increment adjusts temperature "0.1 deg."
Switches off Lamp 2, no adjust allowed.
5-30