Verifying the Load Balancing/RSL Configuration
1 Boot the server and ignore these messages:
IN LAN Hello L1 Packet Received in Circuit
3c985_1_E82 from DL411
This message appears if you load ipxrtr and the
3Com server NIC driver:
A mismatched source node/data-link address
addr/addr in CSNP L1 packet received on
circuit board_name from server_name.
2 If other error messages appear, make corrections
in the appropriate .NCF files and reboot.
Verifying the Installation and Configuration
To verify that the 3Com server NIC driver has been
properly loaded on the NetWare server, perform the
following procedure:
1 At the system prompt, enter:
load monitor
The NetWare Monitor screen appears.
2 From the Available Options menu, select
LAN/WAN Information.
The Available LAN Driver menu appears. If the driver has
been properly loaded, the driver, slot number, and frame
types associated with the driver appear on this menu.
3 Select a driver to view its associated statistics.
A functioning driver displays packets being sent and received.
To verify that the server is communicating over the
network, complete the following procedure:
1 Set up a NetWare client on a LAN supported by
the server to be tested.
2 Log in or map to the server.
If you cannot log in or map to the server, the link is
not functional.
If the link is functional, the following message appears:
Link integrity test for primary slot # xxxxx
passed.