Service Call Conditions
If the problem is with electrical circuit boards, disconnect the connectors first. Then
reconnect the connectors before you replace the PCBs.
If the problem is with a motor lock, first examine the mechanical load. Then
replace motors or sensors.
4.1.2 SC CODE DESCRIPTIONS
FGATE error
The PFGATE ON signal does not
assert within 1 second.
230
B
The PFGATE ON signal still assert
within 7 seconds, after processing the
image in a normal job
Charge roller current leak
The PWM duty output exceeded 60%
302
B
for longer than 200 ms, indicating a
leak in the charge roller current.
Polygon motor error
The polygon motor did not enter the
lock state within 10 sec. after it
switched on.
-or-
Once the polygon motor was detected
320
B
in the lock state after started to rotate,
within 0.2 sec. it entered the unlock
state.
-or-
After the polygon motor switched off, it
did not enter unlock state within 3 sec.
M001
Defective engine board
Defective controller board
Disconnect harness
Cartridge (charge roller)
defective
High voltage supply board
defective
Defective cartridge connection
Polygon motor
Polygon motor cable
4-2
SM