4. TROUBLESHOOTING

4.1 SERVICE CALL CONDITIONS

4.1.1 SUMMARY
There are 4 levels of service call conditions
Level
Definition
Fusing unit SCs shown on the
operation panel. The machine is
A
disabled. The user cannot reset the
SC.
These SCs disable only the features
that use the defective item. The
user does not see these SCs in
B
usual conditions. But, they are
shown on the operation panel when
the defective feature is used.
SCs that are not shown on the
C
operation panel. They are recorded
internally.
These SCs are shown on the
operation panel. To reset these
SCs, turn the operation switch or
D
main power switch off and on.
These SCs are shown again if the
error occurs again.
SM
Service Call Conditions
Reset Procedure
1.
Do SP5810 and press [#Enter].
2.
When "execute" is displayed, press
[#Enter] again.
3.
Press [Escape].
4.
Turn the machine power off/on.
Set the main power switch to "off" then
to "on".
Recorded only.
Set the operation switch or the main
power switch to "off" then to "on".