5. Turn the two (2) latches to the release position (see Number 1) and lift the backplane to disengage
and remove the backplane from the node by lifting straight up and out (see Number 2).
3.8.2

Installing the Drive Backplane

To install the drive backplane, do the following:
1. Connect the ambient sensor cable (see Figure 31).
2. Align the backplane with the backplane slots in the side walls of the node (see Number 1).
3. Lower the backplane into the slots in the chassis and push the two latches down parallel to the
baseboard (see Number 2).
Note: Make sure the ambient sensor cable is routed through the slot on the bottom backplane.
4. Connect the SAS/SATA and power cables to the backplane (see Figure 31).
38
Intel® Server System R2600SR Setup and Service Guide

Figure 32. Removing the drive backplane

Figure 33. Installing the drive backplane