Comtech EF Data CDM-710G Installation And Operation Manual page 232

High-speed satellite modem
Table of Contents

Advertisement

CDM-710G High-Speed Satellite Modem
Remote Control
Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Rx Signal Level
N/A
3 bytes
Rx Demod
RSW=
3 bytes
Acquisition
Sweep Width
Gigabit Learning
SLM
2 bytes
Mode
Gigabit Auto
SCX
2 bytes
Autocrossover
Serial Number
N/A
9 bytes
Software
N/A
5 bytes
Revision
Real-time Clock
TIM=
6 bytes
Time
Temperature
N/A
3 bytes
Description of Arguments
Query
Query Only.
Unit returns the value of the Rx signal level, in dBm, between +3.0 and –
99.0 dBm, where;
xxx is the Rx signal level.
Examples:
RSL=+03
RSL=-41
Command or Query.
Rx ± acquisition sweep range of demodulator, in kHz, ranging from ± 1 to ±
100 kHz.
Example: RSW=009 (selects ± 9 kHz)
Command or Query.
s=Slot 2 Only
a=1 GBEI Learning Enabled.
a=0 GBEI Learning Disabled
Command or Query.
s=Slot 2 Only
a=1 GBEI Cable Auto Crossover Enabled.
a=0 GBEI Cable Auto Crossover Disabled
Query Only.
Used to query the unit 9-digit serial number. Unit returns its S/N in the form
xxxxxxxxx.
Example: SNO=176500143
Query Only.
Unit returns the value of the internal software revision installed in the unit,
in the form: Boot:X.X.X Bulk1:Y.Y.Y Bulk2: Z.Z.Z
Example: SWR=Boot:1.0.3 Bulk1:1.0.1 Bulk2:1.0.0
Command or Query.
A time in the form hhmmss, indicating the time from midnight, where:
hh = hours (00 to 23)
mm = minutes (00 to 59)
ss = seconds (00 to 59)
Example: TIM=231259 (23 hours:12 minutes:59 seconds)
Query Only.
Unit returns the value of the internal temperature, in the form of sxxx
(degrees C). Where s is the sign and and xxx is the number of degrees.
Example: TMP=+026
A–42
Query
Response to
(Instruction
Response to Query
Command
Code and
Qualifier)
RSL?
RSL?
RSL=xxx
RSL*
RSL#
RSW=
RSW?
RSW=xxx
RSW?
(see description of
arguments)
RSW*
RSW#
SLM=
SLM?s
SLM=a
SLM#
SLM?
SLM*
SCX=
SCX?s
SCX=a
SCX#
SCX?
SCX*
SNO?
SNO?
SNO=xxxxxxxxx
SNO*
SNO#
SWR?
SWR?
SWR=Boot:X.X.X
SWR*
Bulk1:Y.Y.Y Bulk2:Z.Z.Z
SWR#
TIM=
TIM?
TIM=hhmmss
TIM?
TIM*
TIM#
TMP?
TMP?
TMP=sxxx
TMP*
TMP#
Revision 1
MN-CDM710G

Advertisement

Table of Contents
loading

Table of Contents