NOTE:
Provide adequate clearance in front of the fireplace to access the control valve, install and attach gas line, install a fan, etc..
Do not obstruct the upper and lower convection air passage areas to allow proper ventilation air around the fireplace. Room air enters
through the lower passage, is heated and exits at the upper passage. Blocking these passages may result in overheating the fireplace
creating a potentially hazardous situation.

PREPARE THE FIREPLACE

HORIZONTAL VENTING CONFIGURATIONS USING A 90-DEGREE ELBOW DIRECTLY OFF THE TOP OF THE FIREPLACE:
1.
Position and install the 90-degree elbow per
manufacturer's installation instructions.
ATTACH THE HORIZONTAL VENT HEAT SHIELD:
1.
Loosen, but do not remove the (2) screws at the top of the
fireplace as shown in Figure 8A.
Figure 8A
VERTICAL TERMINATIONS:
RESTRICTOR USAGE (optional):
1.
The restrictor plate (included in the fireplace components
packet) should be placed inside the 5" flue collar on the top of
the fireplace before connection of the chimney to the fireplace
is made.
a.
Bend the (3) tabs on the restrictor plate far enough so that
it will securely fit inside the groove on the 5" collar on the
fireplace. (Note: The tabs should be in the 'up' position.)
Refer to Figure 9.
2.
Slide the (2) slots on the horizontal vent heat shield under the
screws. Re-tighten the screws to secure in place. Refer to
Figure 8B.
Figure 8B
Figure 9