Position The Fireplace; Remove The Glass Assembly; Vent System Installation - kozy heat Two Harbors 55616 Installation And Operating Manual

Direct vent gas fireplace
Table of Contents

Advertisement

POSITION THE FIREPLACE

1.
Place the fireplace into position.
2.

REMOVE THE GLASS ASSEMBLY.

Figure 11

VENT SYSTEM INSTALLATION:

Install the vent system components for your specific venting configuration. Follow the vent system manufacturer's installation instructions in
conjunction with the venting requirements in this installation manual.
HORIZONTAL & VERTICAL TERMINATIONS: All firestops, support brackets, etc. must be used as specified by the vent system manufacturer.
All clearances and venting requirements as specified in this manual must be followed. Secure the vent system to the fireplace - see page #4.
Refer to pages #4 - #8 of this installation manual for complete venting requirements and restrictions.
HORIZONTAL TERMINATIONS:
IMPORTANT:
Framing header may be installed after the
fireplace is placed into position.
IMPORTANT: PLACE HEADER IN THE 'UP' POSITION TO
MAINTAIN PROPER CLEARANCE FROM VENT SYSTEM TO
COMBUSTIBLES.
NOTE:
Shown in horizontal vent configuration
The Kozy Heat wall pass-thru, part #800-WPT, must be used on all horizontal vent applications regardless
of which vent system you are using.
Figure 10
A.
Locate the spring-loaded latch bars securing the glass
assembly at the top & bottom of the firebox.
CAUTION: TO PREVENT THE GLASS ASSEMBLY FROM
FALLING FROM THE FIREPLACE AND BECOMING
DAMAGED, FOLLOW THESE DIRECTIONS EXACTLY
WHEN REMOVING THE GLASS ASSEMBLY.
B.
Pull the bottom latch bar out, then 'down' to release
the glass assembly at the bottom.
C.
Pull the top latch bar out, then 'up' to release the glass
assembly at the top.
D.
Lift the glass assembly off from the front of the
fireplace and set aside where it will not be broken.
E.
Remove the log package from the firebox and set
aside.
Page 11