INSTALLATION INSTRUCTIONS

THE FOLLOWING COMPONENTS MUST BE REMOVED FROM THE FIREPLACE PRIOR TO INSTALLATION OF THIS FAN. REFER TO THE
FIREPLACE INSTALLATION MANUAL FOR ASSISTANCE IF NECESSARY.
1.
Full door face. Refer to page #18 if necessary.
2.
Glass assembly.
NOTE:
Millivolt board has been removed for clarity. It is not necessary to remove the millivolt board to install this optional fan kit.
INSTALL THE FAN:
1.
Slide the fan through the lower air passage opening (right side of the valve), placing it at the back of the fireplace.
NOTE: The fan bracket is held in position by a magnetic strip attached to the bottom of the bracket.
2.
OPTIONAL: Remove the (2) screws securing the access panel (with electrical box & romex connector installed) from right side wall
of the fireplace.
3.
Insert 115V wiring (with ground) through the romex connector and wire to the receptacle / speed control assembly.
4.
Re-install the electrical access panel and secure with the (2) screws removed.
5.
Secure speed control / receptacle assembly into the electrical box with the screws provided.
6.
Place the temperature control switch on the bottom of the firebox. Refer to Figure 13.
7.
Plug the fan cord into receptacle in the electrical box.
8.
Turn the on/off speed control counter-clockwise until it 'clicks'. This is the 'OFF' position.
9.
Turn the speed control 'ON' by turning the knob clockwise past the 'click' - this is the highest setting.
10. Re-install the glass assembly.
11. Re-install the full door face.
12.
NOTE: The fan will not operate unless the speed control has been turned 'ON' and sufficient heat has been applied to the temperature control switch. The
fan will turn 'ON' and 'OFF' automatically when the fireplace heats and cools. Adjust fan to desired speed while it is running.
TEMPERATURE CONTROL SWITCH POSITION: Prior to adjusting the temperature control switch, unplug the 3-prong plug on the fan cord from the receptacle. Adjust
the position of the temperature control switch to a warmer location under the firebox to turn the fan 'ON' sooner or move it to a cooler location under the firebox to turn
the fan 'ON' later. The fan will turn on when the sensor in the temperature control switch reaches 110
adjustment, plug the 3-prong plug on the fan cord into the receptacle.
NOTE: This appliance must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-Current edition, or the Canadian Electrical Code, CSA C22.1.
Temperature control
Fan Assembly
Receptacle / speed control
switch
Figure 13
o
F and will turn 'OFF' when the sensors reach 90
Page 13
o
F. After