WHEN VERTICALLY TERMINATING, THE MINIMUM CHIMNEY HEIGHT ABOVE THE ROOF LINE IS DETERMINED BY THE
FOLLOWING CHART:
Roof Pitch
Flat to 6/12
6/12 to 9/12
10/12 to 12/12
CAUTION: This gas appliance must not be connected to or joined with any chimney flue serving any other appliance.
RESTRICTOR USAGE:
A restrictor plate has been included with this fireplace and usage may be required depending on your specific venting configuration, i.e.:
number of elbows, length of vertical vent run, etc.. All of these can affect proper draft of the vent system and the burner operation of a
fireplace. Installing a restrictor may be necessary to resolve the problem, even though it may not be required under 'normal conditions'.
Refer to page #10 for complete installation instructions.
NOTE:
Horizontal Vent Heat shield is not used on
Vertical venting configurations.
Figure 6
Minimum Chimney Height
1 ft.
2 ft.
4 ft.
Roof Pitch
13/12 to 16/12
17/12 to 21/12
Page 8
Minimum Chimney Height
6 ft.
8 ft.