Installation Requirements - kozy heat Two Harbors 55616 Installation And Operating Manual

Direct vent gas fireplace
Table of Contents

Advertisement

SPECIFICATIONS
Height to top of stand-off (without face) . . . . . . . . . . . . . . . 32 ½"
Front width (including stand-offs / without face) . . . . . . . . 19 ½ "
Back width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1/4"
Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3/8"

INSTALLATION REQUIREMENTS:

Minimum clearances from the fireplace to combustible materials:
From face top:
Fireplace bottom to flooring:
Fireplace side stand-offs to adjacent sidewall: 1"
* NOTE: The fireplace requires a ½" space between it and the framing at the sides & back. The framing material may touch the sides of the
stand-offs, but no material should be placed between the stand-offs
HEARTH REQUIREMENTS - Figure 2A.
When the fireplace is installed on carpet, tile or other combustible material, it must
be installed on a metal or wood panel extending the full width & depth of the
fireplace.
The minimum platform size is 19 3/4" wide X 14 7/8" deep.
If a hearth extension is desired, combustible materials may be used.
If installed in front of carpet or other flooring, the fireplace must be raised so
the bottom of the fireplace is above the carpet or flooring material surface.
MINIMUM ENCLOSURE HEIGHT:
The minimum enclosure height from the base of the fireplace
to inside top of the enclosure must be at least 47". Refer to Figure 2A.
Full Door Face Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5/16"
Full Door Face Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21"
Refer to Diagrams for additional measurements.
Figure 1
1"
From fireplace left & right sides & back:
0"
Fireplace base to ceiling:
Minimum enclosure height:
.
Figure 2A
Page 2
1/2" *
52"
47"