Electrical Specifications For 55 V To 300 V Models - Xantrex XKW 8-350 Operating Manual

Xkw 3000 watt series programmable dc power supply
Table of Contents

Advertisement

Features and Specifications
Specifications
Table 1.3 Electrical Specifications for 55 V to 300 V Models
Models
Output Ratings:
Output Voltage
Output Current
Output Power
1
Line Regulation:
Voltage
Current
2
Load Regulation:
Voltage
Current
Meter Accuracy:
Voltage
Current
OVP Adjustment Range:
Output Noise and Ripple:
(20 Hz - 20 MHz)
Voltage (p-p)
Voltage (rms)
Analog Programming Accuracy
Voltage (1% of Vmax)
Current (1% of Imax)
3
Drift:
Voltage
Current
Temperature Coefficient:
Voltage
Current
1. For input voltage variation over the AC input voltage range, with constant rated load.
2. For 0-100% load variation, with constant nominal line voltage.
3. Maximum drift over 8 hours with constant line, load and temperature, after 90 minute warm-up.
4. Change in output per °C change in ambient temperature, with constant line and load.
22
55-55
0-55 V
0-55 A
3025 W
55 mV
55 mA
55 mV
55 mA
0.65 V
0.65 A
2.75-60.5 V
150 mV
20 mV
550 mV
550 mA
27.5 mV
27.5 mA
4
11 mV
16.5 mA
60-50
80-37
0-60 V
0-80 V
0-50 A
0-37 A
3000 W
2960 W
60 mV
80 mV
50 mA
37 mA
60 mV
80 mV
50 mA
37 mA
0.7 V
0.9 V
0.6 A
0.47 A
3-66 V
4-88 V
150 mV
150 mV
20 mV
20 mV
600 mV
800 mV
500 mA
370 mA
30 mV
40 mV
25 mA
18.5 mA
12 mV
16 mV
15 mA
11.1 mA
Operating Manual for XKW 3kW Series Power Supply
150-20
300-10
0-150 V
0-300 V
0-20 A
0-10 A
3000 W
3000 W
150 mV
300 mV
20 mA
10 mA
150 mV
300 mV
20 mA
10 mA
1.6 V
3.1 V
0.30 A
0.20 A
7.5-165 V
15-330 V
200 mV
300 mV
30 mV
30 mV
1.5 V
3.0 V
200 mA
100 mA
75 mV
150 mV
10 mA
5 mA
30 mV
60 mV
6.0 mA
3.0 mA

Hide quick links: