Operation
Configuring for Remote Programming, Sensing, and Monitoring
Internal Switch and Jumpers If you should need to change any of the standard
configurations of the supply, internal jumpers JMP1 and JMP2, and switch SW1
enable you to select:

Figure 3.2 Internal Jumpers and Switch (Default Settings Shown)

50
Voltage and Current Programming Scale Factor
Over Voltage Protection (OVP) Programming Mode and Scale
Voltage and Current Monitor Range
Shutdown Circuit Logic
SELECTS OVP
PROGRAMMING RANGE
CLOSED = 0-10V
OPEN = 0-5V
SELECTS SHUTDOWN
CIRCUIT LOGIC
CLOSED = NEGATIVE LOGIC
OPEN = POSITIVE LOGIC
SELECTS OVP
PROGRAMMING MODE
CLOSED = LOCAL
OPEN = REMOTE
SELECTS VOLTAGE
PROGRAMMING INPUT
B-C = 0-5V
A-B = 0-10V
SW1
OPEN (OFF)
CLOSED (ON)
8
7
6
5
4
C
B
A
JMP1
RANGE
Operating Manual for XKW 3kW Series Power Supply
SELECTS VOLTAGE
MONITOR RANGE
CLOSED = 0-5V
OPEN = 0-10V
NOT USED
3
2
1
SELECTS CURRENT
MONITOR RANGE
CLOSED = 0-5V
OPEN = 0-10V
NOT USED
C
B
A
JMP2
SELECTS CURRENT LIMIT
PROGRAMMING INPUT
RANGE
B-C = 0-5V
A-B = 0-10V