Programming Output Voltage And Current Limit With The Rem/Loc Switch - Xantrex XKW 8-350 Operating Manual

Xkw 3000 watt series programmable dc power supply
Table of Contents

Advertisement

Notes for Programming with a 0-10V Source:
1. Programming with a 0-10V external voltage source requires that you reset
2. Resetting internal jumpers may require a recalibration of the programming
"Configuring for Remote Programming, Sensing, and Monitoring" on page 48
explains how to use the front panel REM/LOC switch, how to reconfigure or make
connections to the external J3 connector, and how to access internal jumpers JMP1
and JMP2 to change their settings.
Programming
The front panel REM/LOC (Remote/Local Programming) switch will allow you to
Output
switch back and forth between remote and local operation when programming output
voltage and current limit with external voltage and/or current sources.
Voltage and
Current Limit
For programming output voltage and current limit using the REM/LOC switch:
with the
REM/LOC
1. Connect the programming source between pins 9 (voltage programming
Switch
2. Connect the programming source between pins 10 (current limit programming
3. Set the front panel REM/LOC switch to REM.
Revision A
WARNING
Exercise caution when resetting internal jumpers. Follow the procedures for
removing the cover and resetting jumpers in
page 51
internal jumpers JMP1 and/or JMP2 in addition to performing any external
operations.
circuit to maintain programming accuracy. See
Accuracy" on page
82.
input/positive) and 12 (return).
input/positive) and 12 (return).
Remote Programming of Output Voltage and Current Limit
"Resetting Jumpers and Switch" on
"Calibrating for Programming
Operation
55

Hide quick links:

Advertisement

Table of Contents
loading