Programming Ovp With An External Voltage Source; Figure 3.13Remote Programming Of Ovp - Xantrex XKW 8-350 Operating Manual

Xkw 3000 watt series programmable dc power supply
Table of Contents

Advertisement

Programming
To set the OVP trip level with a 0-5Vdc or a 0-10Vdc external voltage source:
OVP with an
1. Ensure the power supply is turned OFF and that both the AC power source and
External
Voltage
Source
2. Set the power supply's internal switch SW1-7 OPEN. Ensure switch SW1-6 is
3. Connect the external voltage source between pin 3 (positive) and pin 12 (return)
4. Set the external programming source voltage to maximum (5 Vdc or 10 Vdc).
5. Turn the power supply ON and turn the front panel voltage control clockwise
6. Slowly reduce the external programming voltage until the red OVP LED lights
Note:When OVP is programmed by an external voltage source, the OVP set point
can be approximated using the following formula:
where:
.

Figure 3.13Remote Programming of OVP

Revision A
the load are disconnected. Allow five (5) minutes to elapse to dissipate stored
energy before resetting switches or making connections. Refer to
for Remote Programming, Sensing, and Monitoring" on page 48
for removing the cover and resetting switches or making J3 connections.
set to OPEN for 0-5Vdc OVP programming (factory default setting) or set it to
CLOSED for 0-10Vdc OVP programming. See
on the J3 connector on the rear panel. See
of shielded-twisted pair wiring is recommended. Ground the shield to J3
connector pin 6 or to the chassis using one of the J3 connector screws.
until the voltmeter shows the desired trip voltage.
and the power supply shuts down.
OVP Set Point + 2% = (V
V
is the power supply model-rated voltage
O
PGM
is the external voltage source maximum voltage (5 or 10)
SCALE
V
is the remote OVP program voltage setting (0 to 5Vdc or 0 to 10Vdc)
PGM
8 7 6 5 4 3 2 1
(with a 0-5Vdc External Voltage Source)
Using Over Voltage Protection (OVP)
Figure 3.13
Figure 3.13
/ PGM
)V
O
SCALE
PGM
0 - 5 V
Operation
"Configuring
for instructions
and
Figure
3.14.
and
Figure
3.14. The use
J3
+