Noise And Impedance Effects; Making The Connections; Connecting Single Loads - Xantrex XKW 8-350 Operating Manual

Xkw 3000 watt series programmable dc power supply
Table of Contents

Advertisement

Noise and
To minimize noise pickup or radiation, use shielded-twisted pair wiring of as short a
Impedance
length as possible for load wires. Connect the shield to the chassis via a rear panel
mounting screw. Where shielding is impossible or impractical, simply twisting the
Effects
wires together will offer some noise immunity. When using local sense connections,
use the largest practical wire size to minimize the effects of load line impedance on
the regulation of the supply.
Making the
Connections
Make load connections to the power supply at the positive and negative output
terminals (or bus bars) at the rear of the power supply. See
Supply Rear Panel" on page
mounting holes on each bus bar terminal as specified in the following table.
Load Wiring Mounting
Holes
One (1) per terminal
Two (2) per terminal
Connecting
Figure 2.5
Single Loads
single loads. Local sense lines shown are default J3 connections. Refer to
"Connecting Remote Sensing Lines" on page 44
sense line shield.
Revision A
CAUTION
!
When making connections to the bus bars, ensure each terminal's mounting
hardware and wiring assembly is placed to avoid touching the other terminal and
shorting the power supply output. Heavy connecting cables must have some form of
strain relief to avoid loosening the connections or bending the bus bars.
and
Figure 2.6
20. The power supply provides three load wiring
Diameter
0.332 in.
0.190 in. on 0.5 in. centers #10
show recommended load and sensing connections for
Load Connection
Figure 1.2, "Power
Hardware Size
1/4 in.
(5/16 in. for 8V + 12V models)
for more information about the
Installation
39