Electrical Specifications-Summary - Xantrex XDC Series Operating Manual

6000 watt slave power supply
Table of Contents

Advertisement

TM-XDSL-01XN.book Page 24 Tuesday, November 5, 2002 3:22 PM
Specifications and Characteristics
Electrical Specifications—Summary
Electrical Specifications—Summary
Table A.1Specifications for 10V to 60V Models
Models
Output Ratings:
1
Output Voltage
2
Output Current
Output Power
3
Line Regulation:
Voltage (0.01% of Vmax)
Current (0.05% of Imax)
4
Load Regulation:
Voltage (0.05% of Vmax + 5 mV)
Current (0.1% of Imax + 20 mA)
Output Noise (0–20 MHz):
Voltage (p–p)
Output Ripple (rms):
Voltage
5
Current
OVP Adjustment Range:
(0% to 103% of Vmax)
6
Efficiency:
1. Minimum output voltage is <0.3% of rated voltage at zero output setting.
2. Minimum output current is <0.2% of rated current at zero output setting when measured with rated load resistance.
3. For input voltage variation over the AC input voltage range, with constant rated load.
4. For 0–100% load variation, with constant nominal line voltage.
5. Current mode noise is measured from 10% to 100% of rated output voltage, full current, unit in CC mode.
6. Typical efficiency at nominal input voltage and full output power.
Table A.2Drift Specifications for 10V to 60V Models
Models
1
Drift (30 minutes):
Voltage (0.04% of Vmax)
Current (0.6% of Imax)
2
Drift (8 hours):
Voltage (0.02% of Vmax)
Current (0.04% of Imax)
Temperature Coefficient:
Voltage (0.04% of Vmax/°C)
Current (0.06% of Imax/°C)
1. Maximum drift over 30 minutes with constant line, load, and temperature, after power on.
2. Maximum drift over 8 hours with constant line, load, and temperature, after 30 minute warm-up.
3. Change in output per °C change in ambient temperature, with constant line and load.
24
10-600
0–10 V
0–600 A
6000 W
1 mV
300 mA
10 mV
620 mA
75 mV
10 mV
3100 mA
0–10.3 V
0.85
10–600
4 mV
3600 mA
2 mV
240 mA
3
4 mV
360 mA
20-300
30-200
40-150
0–20 V
0–30 V
0–40 V
0–300 A
0–200 A
0–150 A
6000 W
6000 W
6000 W
2 mV
3 mV
4 mV
150 mA
100 mA
75 mA
15 mV
20 mV
25 mV
320 mA
220 mA
170 mA
75 mV
75 mV
75 mV
10 mV
12 mV
15 mV
1600 mA
1000 mA
750 mA
0–20.6 V
0–30.9 V
0–41.2 V
0.87
0.87
0.87
20–300
30–200
40–150
8 mV
12 mV
16 mV
1800 mA
1200 mA
900 mA
4 mV
6 mV
8 mV
120 mA
80 mA
60 mA
8 mV
12 mV
16 mV
180 mA
120 mA
90 mA
Operating Manual for XDC Series Slave Power Supply
60-100
0–60 V
0–100 A
6000 W
6 mV
50 mA
35 mV
120 mA
100 mV
15 mV
450 mA
0–61.8 V
0.89
60–100
24 mV
600 mA
12 mV
40 mA
24 mV
60 mA

Advertisement

Table of Contents
loading

Table of Contents