Specifications; Electrical Specifications - Xantrex XKW 8-125 Operating Manual

Xkw 1000 watt series programmable dc power supply
Table of Contents

Advertisement

Specifications

These specifications are warranted over a temperature range of 0 °C to 50 °C.
Electrical
Specifications
Specifications are subject to change without notice.
Table 1.2 Electrical Specifications for 8 V to 60 V Models
Models
Output Ratings:
Output Voltage
Output Current
Output Power
1
Line Regulation:
Voltage
Current
2
Load Regulation:
Voltage
Current
Meter Accuracy:
Voltage
Current
OVP Adjustment Range:
Output Noise and Ripple:
(20 Hz - 20 MHz)
Voltage (p-p)
Voltage (rms)
3
Drift:
Voltage
Current
Temperature Coefficient:
Voltage
Current
Nominal Output Capacitance:
Nominal Capacitance
(Output to Chassis):
1. For input voltage variation over the AC input voltage range, with constant rated load.
2. For 0-100% load variation, with constant nominal line voltage.
3. Maximum drift over 8 hours with constant line, load and temperature, after 90 minute warm-up.
4. Change in output per °C change in ambient temperature, with constant line and load.
Release 2.2
8-125
0-8 V
0-125 A
1000 W
8 mV
125 mA
8 mV
125 mA
0.09 V
1.35 A
0.4-8.8 V
50 mV
10 mV
4 mV
62.5 mA
4
1.6 mV
37.5 mA
66,000
µF
200n
F
20-50
33-33
0-20 V
0-33 V
0-50 A
0-33 A
1000 W
1089 W
20 mV
33 mV
50 mA
33 mA
20 mV
33 mV
50 mA
33 mA
0.3 V
0.43 V
0.6 A
0.43 A
1.0-22 V
1.65-36.3 V
50 mV
100 mV
10 mV
10 mV
10 mV
16.5 mV
25 mA
16.5 mA
4 mV
6.6 mV
15 mA
9.9 mA
30,000
10,000
µF
µF
270n
300n
F
F
Features and Specifications
Specifications
40-25
60-18
0-40 V
0-60 V
0-25 A
0-18 A
1000 W
1080 W
40 mV
60 mV
25 mA
18 mA
40 mV
60 mV
25 mA
18 mA
0.5 V
0.7 V
0.35 A
0.28 A
2-44 V
3-66 V
100 mV
150 mV
10 mV
20 mV
20 mV
30 mV
12.5 mA
9 mA
8 mV
12 mV
7.5 mA
5.4 mA
10,000
10,000
µF
250n
250n
F
F
µF
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents